Office Buildings Glass Facades Excitation under Hot and Dry Climates: A Numerical and Experimental Study

نویسندگان

چکیده مقاله:

The purpose of this research is to reviews the thermal comfort condition of full glass south view official buildings in warm and dry zones and conclusion of buildings disadvantage in thermal waste and after all presenting an ideal plan with appropriate solution. To reach to that goal first of all the effective factors on wasting energy were reviewed then the temperature testing with thermometer was done and the data were analyzed by energy plus software. So, the studies method is based on statistics and experiments. The results show the main reason of energy wasting for buildings with full glass view is direct sun. After the reviews studies and simulations the conclusion is that this kind of view is known for having issues for thermal comfort, natural ventilation and glare. Specially buildings with bright shells in warm and dry zones. These issues made us to find solutions for this problem. After considering several solutions, we considered a 180° rotation of the building, in order to put the glass view on the north side of the building, which doesn’t have the sun heat. The result show that in hot and dry zones in order to prevent the building flushing, glass view with high percentage, should not be used. After the rotation simulation, the results showed the thermal waste which was the main reason of energy waste, were reached to a normal level.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Research of Interindividual Differences in Physiological Response under Hot-Dry and Warm-Wet Climates

Somatotype and habitus parameters may affect physiological control system, so the changes of physiological parameters are not the same when various people work in hot-dry and warm-wet climates. In this paper, a chamber built in Tianjin University was used to simulate comfortable, hot-dry and warm-wet climates. Sixty healthy university students were selected as subjects who were divided into fou...

متن کامل

Architectural Design Optimization of School Buildings for Reduction of Energy Demand in Hot & Dry Climates of Iran

School buildings as a major part of public buildings are considered as one of the basic consumers of energy in Iran. Based on building typology and occupancy patterns, school buildings have a great potentiality for energy optimization while providing thermal comfort. This study investigates the architectural design parameters such as orientation, optimum window to wall ratio, space organization...

متن کامل

Investigating the Climate Change on Architecture Based on Mahoney Index, Case Study: Tehran Hot and Dry Climates

City and human are two different human-made and natural systems which has an effect on each other. The formation of a residence depends on the climatic conditions. Construction of a residence shows that people have adapted themselves and their activities to it; while the climatic conditions play an important role in comfort in human environments. Thus, the buildings and environmental spaces sho...

متن کامل

Evaluation of the environmental stress index (ESI) for hot/dry and hot/wet climates.

Recently, a novel environmental stress index (ESI) which is composed from commonly used meteorological variables: ambient temperature (T(a)), relative humidity (RH), and solar radiation (SR) was suggested as follows: ESI = 0.63T(a)-0.03RH+0.002SR+0.0054(T(a) x RH)-0.073(0.1+SR)(-1); (degrees C) The purpose of the present study was to evaluate and validate the ESI for hot dry and hot wet climati...

متن کامل

Experimental and Numerical Study of Energy Absorption Capacity of Glass Reinforced SCC Beams

Various experimental studies have been carried out on glass fiber reinforced concrete (GFRC), but in limited studies, the behavior of this type of concrete is evaluated using finite element method (FEM). In this study an analysis model is presented for predicting energy absorption capacity of glass fiber reinforced self-compacting concrete (GFRCSCC) beams and the results are compared with exper...

متن کامل

Fading and Silver Mirroring in a Dry Plate Glass Negative

Dry plate glass negatives are important part of the cultural, historical and visual heritage in history of Iran. Structural changes due to factors affected them over time, can cause deterioration in the image. Identifying deteriorations in dry plate glass negatives can help to provide better solutions in preserving them. The investigation of sample by Fourier transform infrared spectroscopy ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 20  شماره 4

صفحات  5- 25

تاریخ انتشار 2018-03

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023