Relevance between MRI longitudinal relaxation rate and gadolinium concentration in Gd3+/GO/alginate nanocomposite

نویسندگان

  • Baharak Divband Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran| Inorganic Chemistry Department, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
  • Ensiyeh Shafaei Molecular Medicine Research Center, Tabriz University of Medical Sciences, Tabriz, Iran| Department of Radiology, Tabriz University of Medical Sciences, Tabriz, Iran
چکیده مقاله:

Objective(s): Relevance between magnetic resonance imaging (MRI) relaxation rate and concentration of magnetic nanoparticles determines the capability of a nanomaterial to provide MRI contrast. In the present study, alginate was conjugated to gadolinium/graphene oxide nanocomposite to form gadolinium/graphene oxide/alginate nanocomposite, aiming to investigate its effect on the relevance between MRI longitudinal relaxation rate and paramagnetic gadolinium concentration.Materials and Methods: The physicochemical properties of the nanocomposite and its effect on the cell culture were investigated. Moreover, MRI longitudinal relaxation rates were determined based on the corresponding exponential curves, and the graph of their relevance with gadolinium concentration was plotted. Results: The average thickness and sheet size of the nanocomposite were three and 100 nanometers, respectively. The nanocomposite showed high cell viability, even at the relatively high concentration of 75 µg/ml. In addition, a linear correlation was observed between longitudinal relaxation rate and gadolinium concentration. Conclusion: According to the results, the linearity between gadolinium/graphene oxide/alginate nanocomposite and gadolinium concentration, which revealed a high slope, confirmed the potential of the nanocomposite to significantly improve the positive contrast of MR images.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gadolinium enhanced MRI predicts clinical and MRI

11 November 1996 Accepted 20 November 1996 Abstract The aim of the study was to evaluate the predictive power of baseline gadolinium (Gd) enhanced MRI in relation to subsequent clinical and MRI activity. Sixty eight patients with clinically definite relapsing-remitting multiple sclerosis had a baseline Gd enhanced MRI and were followed up clinically and by monthly Gd enhanced MRI for six months...

متن کامل

Longitudinal Association between Serum Leptin Concentration and Glomerular Filtration Rate in Humans

BACKGROUND Obesity is a risk factor for decline in glomerular filtration rate (GFR). One proposed mechanism leading to glomerulopathy is an increase in leptin levels. However, the association between leptin and GFR has never been demonstrated. The aim of this study is to verify whether higher levels of leptin are associated with longitudinal changes of estimated GFR (eGFR). METHODS AND FINDIN...

متن کامل

Magnetic Resonance Imaging Property of Doxorubicin-Loaded Gadolinium/13X Zeolite/Folic Acid Nanocomposite

Background: Magnetic resonance imaging (MRI) using nanostructures has been a proper method for tumor targeting purposes. Different MRI nanomaterials, targeting agents and anticancer drugs have been used for targeting of tumors. Objectives: This study aims to consider the MRI property of doxorubicin (DOX)-loaded gadolinium/13X zeolite/folic acid (Gd3+/13X/FA) nanocomposite.<br /...

متن کامل

MRI assessment of LV relaxation by untwisting rate

Dong, Sheng-Jing, Paul S. Hees, Cynthia O. Siu, James L. Weiss, and Edward P. Shapiro. MRI assessment of LV relaxation by untwisting rate: a new isovolumic phase measure of t. Am J Physiol Heart Circ Physiol 281: H2002–H2009, 2001.—Most noninvasive measures of diastolic function are made during left ventricular (LV) filling and are therefore subject to “pseudonormalization,” because variation i...

متن کامل

Cross-sectional and longitudinal association between hemoglobin concentration and hypertension

We investigated the cross-sectional and longitudinal associations between hemoglobin concentration and hypertension in a Korean population.Between 2006 and 2013, we examined 4899 participants with mean age of 56.6 years (range 35-88 years) from a rural community. We excluded 298 participants with a history of myocardial infarction or stroke and 264 participants with very low hemoglobin levels (...

متن کامل

cohesion and cohesive devices in a contrastive analysis between ge and esp texts

the present study was an attempt to conduct a contrastive analysis between general english (ge) and english for specific purposes (esp) texts in terms of cohesion and cohesive devices. to this end, thirty texts from different esp and ge textbooks were randomly selected. then they were analyzed manually to find the frequency of cohesive devices. cohesive devices include reference, substitution, ...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 4

صفحات  263- 268

تاریخ انتشار 2019-10-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023