Review of techniques for improving the uniformity of dose distribution in total body irradiation (TBI) with parallel – opposed anterior and posterior geometry

نویسندگان

چکیده مقاله:

      Total body irradiation (TBI) is a kind of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression before bone marrow transplantation. As recommended by AAPM dose distribution uniformity in TBI is very important and dose variation must be within ±10% of prescription dose. Patients treatment geometry for TBI techniques fall into two common categories: parallel-opposed anterior/posterior lateral total body irradiation and parallel-opposed lateral total body irradiation. So far several techniques such as use of tissue compensator, dynamic TBI delivery, etc. where implemented in different department around the world to improve dose distribution uniformity. The propose of this paper is to review several techniques that are used around the world for dose uniformity improvement in parallel opposed anterior posterior TBI.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of dose uniformity in total body irradiation (TBI) technique in parallel-opposed anterior/posterior geometry using Varian Clinac 2100C/D linear accelerator

Background: Total body irradiation (TBI) is a technique that is commonly used as a part of the patient conditioning regimen before the bone marrow transplant (BMT). The purpose of this study is to introduce and implement a reasonable TBI technique on the human-like phantom in Imam Khomeini Hospital in Tehran. Methods: The present experimental study was conducted from October 2016 to November 2...

متن کامل

Comparison of different TBI techniques in terms of dose homogeneity

Introduction: Total body irradiation (TBI) is a form of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression. Since the target in TBI is the whole body so a uniform dose distribution throughout the entire body during TBI is necessary. As recommended by AAPM dose variation must be within ±10% of prescription dose. A revi...

متن کامل

Diode calibration for dose determination in total body irradiation

Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...

متن کامل

Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.

Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiven...

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 4

صفحات  299- 310

تاریخ انتشار 2020-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023