Simplex design method in simultaneous spectrophotometric determination of silicate and phosphate in boiler water of power plant and sewage sample by partial least squares

نویسندگان

  • Jahanbakhsh Ghasemi Chemistry Department, Faculty of Sciences, K. N. Toosi University of Technology, Tehran, Iran
  • Masoud Rohani Moghadam Chemistry Department, Faculty of Sciences, Yazd University, Yazd, Iran
  • Shayesteh Dadfarnia Chemistry Department, Faculty of Sciences, Yazd University, Yazd, Iran
چکیده مقاله:

Partial least squares modeling as a powerful multivariate statistical tool was applied tothe simultaneous spectrophotometric determination of silicate and phosphate in aqueoussolutions. The concentration range for silicate and phosphate were 0.02-0.6 and 0.4-3 μg ml-1,respectively. The experimental calibration set was composed with 30 sample solutions using amixture design for two component mixtures. The absorption spectra were recorded from 500 to900 nm. The optimum conditions were obtained by simplex optimization method. The values ofroot mean square error of prediction (RMSEP) for silicate and phosphate using partial leastsquares (PLS) were 0.0017 and 0.02 μg ml-1, respectively. The effects of various cations andanions on detection of silicate and phosphate were investigated. The method was successfullyused for determination of silicate and phosphate in boiler water at power plant, well water andsewage samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

simplex design method in simultaneous spectrophotometric determination of silicate and phosphate in boiler water of power plant and sewage sample by partial least squares

partial least squares modeling as a powerful multivariate statistical tool was applied tothe simultaneous spectrophotometric determination of silicate and phosphate in aqueoussolutions. the concentration range for silicate and phosphate were 0.02-0.6 and 0.4-3 μg ml-1,respectively. the experimental calibration set was composed with 30 sample solutions using amixture design for two component mix...

متن کامل

multiwavelength pectrophotometric determination of stability constants of 4-(2– thiazolylazo) resorcinol (tar) with la3+, y3+ and th4+ in organic-water mixed solvents by chemometrics method & simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares calibration method

تشکیل کمپلکس های tarبا یون های لانتانیم, ایتریم و توریم در دمای 25 درجه، قدرت یونی ثابت 0.1 مولار و در ph ثابت در مخلوط حلال های اتانول – آب و استونیتریل – آب با استفاده از روش های اسپکتروفوتومتری مورد بحث و بررسی قرار گرفت. داده های اسپکتروفوتومتری با استفاده از نرم افزار squad پردازش شدند تا ثابت های تشکیل کمپلکس اندیکاتور – فلز را محاسبه کند. نتایج نشان می دهد که درصد حلال آلی در مخلوط حلال ...

15 صفحه اول

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Spectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares

A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...

متن کامل

Simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares

A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 1

صفحات  1- 9

تاریخ انتشار 2010-12-20

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023