Simulation and patient studies of scatter correction in cardiac SPECT imaging

نویسندگان

  • Ahmad Bitarafan-Rajabi Echocardiography Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
  • Mahsa Noori-Asl Department of Physics, Faculty of Science, University of Mohaghegh Ardabili, Ardabil
چکیده مقاله:

Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the diagnostic accuracy. Material and Methods: In this study, the efficiency of dual-energy window (DEW) correction method regarding the reduction of the undesirable influence of scattering was investigated using the images acquired from the 3D-NCAT simulated phantom, and a group of patients (18 males and 27 females) in both rest and stressful situations. To evaluate the scatter correction method, the image contrasts are calculated before and after applying the scatter correction. Results: The results obtained from this study indicated that the calculated image contrasts enhanced by applying the scatter correction in both simulation and patient studies. In the simulation study, the relative values of increase in image contrast are about 10.15% and 12.58% when using a k value equal to 0.5, and the linear fitting method, respectively. In the patient study, the relative values of increase in image contrasts regarding the rest and stress situations were about 13.63% and 10.84% for females and 12.03% and 10.56% for males, respectively. Conclusion: The utilization of the DEW method for scatter correction of cardiac SPECT images results in an increase in the image contrast and the improvement of the image quality. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte-Carlo simulation for scatter correction compensation studies in SPECT imaging using GATE software package

Simulations using Monte-Carlo packages are increasingly used in Nuclear Imaging, both for PET and SPECT applications. Either for modeling imaging systems or developing algorithms for analysis and improvement of image quantification. The aim of this work is the study of several scatter phenomena and the evaluation and improvement of two scatter correction compensation methods in pixelized scinti...

متن کامل

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

simulation and experimental studies for prediction mineral scale formation in oil field during mixing of injection and formation water

abstract: mineral scaling in oil and gas production equipment is one of the most important problem that occurs while water injection and it has been recognized to be a major operational problem. the incompatibility between injected and formation waters may result in inorganic scale precipitation in the equipment and reservoir and then reduction of oil production rate and water injection rate. ...

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

Detection and Correction of Patient Motion In SPECT Imaging

We have developed an approach to detect and co"ect patient motion that occurs during SPECT imaging. The detection of patient motion is based on frame-to-frame matching, using phase-only matched .filtering (POMF). The co"ection procedure has been designed to co"ect any translational patient motion and alert the operator to other kinds of patient movement. The precision in co"ecting translational...

متن کامل

The Effect of FEW Scatter Correction Method in In-111 Imaging

Introduction: In nuclear medicine imaging, detection of the scattered photons along with the primary photons is one of the major problems that can lead to a decrease in ddiagnostic accuracy. Therefore, use of a suitable scatter correction method can help to improve of the image quality and increase of diagnostic accuracy. The aim of this study is evaluation of five energy wind...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 6

صفحات  430- 438

تاریخ انتشار 2019-11-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023