Spectrophotometric Determination of Formaldehyde in Seawater Samples after In-situ Derivatization and Dispersive Liquid-Liquid Microextraction

نویسندگان

  • Mahmoud Nassiri Department of Marine Chemistry, Faculty of Marine Science, Chabahar Maritime University, Chabahar, I.R. IRAN
  • Massoud Kaykhaii Department of Chemistry, Faculty of Sciences, University of Sistan and Baluchestan, Zahedan, I.R. IRAN
  • Massoud Sepahi Department of Marine Chemistry, Faculty of Marine Science, Chabahar Maritime University, Chabahar, I.R. IRAN
  • Sayyed Hossein Hashemi Department of Marine Chemistry, Faculty of Marine Science, Chabahar Maritime University, P.O. Box 98617-85553 Chabahar, I.R. IRAN
چکیده مقاله:

In this paper, a simple dispersive liquid-liquid microextraction for the extraction and pre-concentration of formaldehyde in seawater samples followed with spectrophotometric is proposed. Formaldehyde was derivatized in situ with acetyl acetone in the presence of ammonium acetate in a single step. Then it was collected into a mixture of ethanol (disperser solvent) and chloroform (extracting solvent). Experimental parameters which have an influence on the extraction, including type and volume of extracting and disperser solvent, pH of sample solution, the concentration of acetyl acetone and ammonium acetate, reaction time and temperature were evaluated and optimized. Under optimal experimental conditions, good linearity was observedin the range of 1-500 µg/Lfor the analyte with a limit of detection of 0.29 µg/L. The proposed method was applied to the analysis of real seawater samples. For spiked samples, good recoveries in the range of 97.7-101.5% were obtained. The relative standard deviations were below 2.1%. Using this method, formaldehyde content in seawater from several locations in Chabahar Bay (southeast Iran) were determined in the range of 1.4 to 4.8 µg/L.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric determination of total phenol in fish muscle after in- situ derivatization and reverse phase dispersive liquid- liquid microextraction

Abstract Reverse phase dispersive liquid- liquid microextraction (RP- DLLME) coupled with spectrophotometry is introduced for the detection of total phenol in the muscle tissue of fishes, such as Sphyraena genie, Otolithes ruber, Rastrelliger kangurta, Lutjanus johnii and Barbus Subquin Cunciatus. Phenols in fish tissues were extracted by ultrasonic bath and derivatization with 4- aminoant...

متن کامل

Spectrophotometric Determination of Copper and Nickel in Marine Brown Algae after Preconcentration with Surfactant Assisted Dispersive Liquid-Liquid Microextraction

A simple, fast and effective pre-concentration method for the determination of Cu (copper) and Ni (nickel) was developed using a Surfactant Assisted Dispersive Liquid-Liquid Microextraction (SA-DLLME) coupled by UV-Vis spectrophotometry in marine brown algae. The complexing agent was 1- (2- pyridylazo) – 2 - naphthol (PAN).The effects of various experimental parameters in the extraction ste...

متن کامل

Determination of Phenol and Carvacrol in Honey Samples Using Dispersive Liquid-Liquid Microextraction and Experimental Design for Optimization

A very simple, rapid and sensitive dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography and flame ionization detection (GC-FID) was developed for the determination of phenol and carvacrol in honey samples. A mixture of 100 µl dichloromethane (extraction solvent) and 0.5 ml acetonitrile (disperser solvent) was rapidly injected into sample solution. Thereby a cloudy sol...

متن کامل

Determination of estrogens in water samples using dispersive liquid liquid microextraction and high performance liquid chromatography.

A new method for the analysis of estrogens including estrone (E1), 17b- estradiol (E2) and diethylstilbestrol (DES) in aqueous samples was performed using dispersive liquid liquid microextraction (DLLME) and high- performance liquid chromatography (HPLC). In order to optimize DLLME some important parameters such as type and volume of extraction and disperser solvent, extraction time, ionic stre...

متن کامل

Determination of Pyrethroid Pesticides in Environmental Samples using Ionic Liquid Dispersive Liquid-Liquid Microextraction

Microextração líquido-líquido dispersiva (DLLME) utilizando líquido iônico (IL) como solvente extrator foi desenvolvida com uma nova abordagem para a determinação de quatro pesticidas piretróides em amostras ambientais de água e solo. Cromatografia líquida de alto rendimento com detector de UV (HPLC-UV) foi empregada na análise cromatográfica. Este método é rápido, fácil de operar e ambientalme...

متن کامل

Spectrophotometric determination of iron species using ionic liquid ultrasound assisted dispersive liquid–liquid microextraction

A simple and efficient method for speciation and determination of iron in different water samples was developed. The method is based on ionic liquid ultrasound assisted dispersive liquid–liquid microextraction (IL-USADLLME) followed by spectrophotometric determination. Fe(II) is complexed with 2,4,6-tri(2’-pyridyl)-l,3,5-triazine (TPTZ), neutralized through ion pair formation with sodium dodecy...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 37  شماره 1

صفحات  89- 97

تاریخ انتشار 2018-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023