The comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size

نویسندگان

  • Hamideh Sadra Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Narjess Ayati Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Ramin Sadeghi Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Seyed Mohsen Seyedi Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Sousan Shafiei Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Vahid-Reza Dabbagh Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
چکیده مقاله:

Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by guidelines. If the validity of 99mTc-DMSA scan for renal size assessment would be established and reported in routine clinical practice, it might be more helpful for diagnostic purposes obviating further modality use in kidney diameter assessment. Methods:70 patients (25 males and 45 females) with the age range of 1 month to 78 years old (Mean ± SD = 18.1 ± 19.3) were included in the study. The longest axis diameter of each kidney was calculated by ultra sonography and planar 99mTc-DMSA scintigraphy. The difference in renal size estimation between US and different projections of 99mTc-DMSA scan was assessed using generalized linear model repeated measurement, pair wise comparison in Post Hoc and Bland-Altman analysis. Results:16 (22.9%) reports were interpreted as normal study, while 54 patients had abnormality at least in one kidney. No significant difference was noticed between the kidney diameters in US as compared to the all views of 99mTc-DMSA scan. Only in the estimation of left kidney size using 99mTc-DMSA scan, there was significant difference between anterior and posterior oblique views as well as between lateral and posterior oblique views. Mean value of the differences (estimated bias) doesn't differ significantly from 0 on the basis of 1-sample t-test. Conclusion: 99mTc-DMSA scintigraphy is an accurate method for renal length measurement with excellent agreement with ultra sonography. Kidney length can be easily measured as a routine processing procedure of a 99mTc-DMSA scan and not only used for more accurate interpretation of the images but also added to the final report as valuable incremental information.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the comparison between ultrasonography and 99mtc-dmsa renal scan in estimation of kidney size

introduction: renal length measurement is an important diagnostic clue in several urinary tract abnormalities. although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mtc-dmsa scintigraphy is of great value. by now, pointing to the renal size in the 99mtc-dmsa scintigraphy report has not been recommended by guidelines. if the validi...

متن کامل

Pancake kidney: An unusual type of renal fusion anomaly found in 99mTc-DMSA renal scintigraphy

A 2.5-year-old boy with a history of the previous incidental finding of an ectopic kidney in ultrasonography was referred to our nuclear medicine center for 99mTc-DMSA renal scintigraphy. The scan showed an unusual type of ectopic fused kidneys on the right side of the lower abdomen. In this anomaly, kidneys were fused completely across the medial portion of both upper and lower pole...

متن کامل

Comparison of IVP-simulator and 99mTc-DMSA renal scaning for renal localization and shielding in candidates for radiation therapy [Persian]

To minimize renal radiation in abdomical radiotherapy, shielding of the kidneys is essential. IVP-simulator is used as an standard method. In this study, we used 99mTc-DMSA to localize and shield the Kidneys and we compared this method with IVP-simulator. The size of the kidneys was proven to be larger as compared with IVP method. The mean of the overlap percentage was 81.88 in right and ...

متن کامل

Assessment of the maximum uptake time of 99mTc-DMSA in renal scintigraphy in rat

Introduction:The optimal imaging time of a radionuclide scintigraphy is the time at which the organ of interest has the maximum uptake of the injected radionuclide. This study was performed to investigate the maximum uptake time of 99mTc-DMSA in rat renal scan. Methods: Renal scintigraphy was performed with 3 mCi of 99mTc-DMSA. Planar ima...

متن کامل

the relationship between academic self-concept and academic achievement in english and general subjects of the students of high school

according to research, academic self-concept and academic achievement are mutually interdependent. in the present study, the aim was to determine the relationship between the academic self-concept and the academic achievement of students in english as a foreign language and general subjects. the participants were 320 students studying in 4th grade of high school in three cities of noor, nowshah...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 24  شماره 1

صفحات  23- 28

تاریخ انتشار 2016-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023