Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

نویسندگان

  • Cyril Jonnes Department of Orthopaedics, Pondicherry Institute of Medical Sciences, Pondicherry, India
  • Shishir Suranigi Department of Orthopaedics, Pondicherry Institute of Medical Sciences, Pondicherry, India
  • Syed Najimudeen Department of Orthopaedics, Pondicherry Institute of Medical Sciences, Pondicherry, India
چکیده مقاله:

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteric fractures (Boyd and Griffin classification). This study was done to compare the functional and radiological outcome of PFN with DHS in treatment of Type II intertrochanteric fractures.   Methods: From October 2012 to March 2015, a prospective comparative study was done where 30 alternative cases of type II intertrochanteric fractures of hip were operated using PFN or DHS. Intraoperative complications were noted. Functional outcome was assessed using Harris Hip Score and radiological findings were compared at 3, 6, and 12 months postoperatively. Results: The average age of the patients was 60 years. In our series we found that patients with DHS had increased intraoperative blood loss (159ml), longer duration of surgery (105min), and required longer time for mobilization while patients who underwent PFN had lower intraoperative blood loss (73ml), shorter duration of surgery (91min), and allowed early mobilization. The average limb shortening in DHS group was 9.33 mm as compared with PFN group which was only 4.72 mm. The patients treated with PFN started early ambulation as they had better Harris Hip Score in the early post-op period. At the end of 12th month, there was not much difference in the functional outcome between the two groups. Conclusion: PFN is better than DHS in type II inter-trochanteric fractures in terms of decreased blood loss, reduced duration of surgery, early weight bearing and mobilization, reduced hospital stay, decreased risk of infection and decreased complications.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

type ii intertrochanteric fractures: proximal femoral nailing (pfn) versus dynamic hip screw(dhs)

background: intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. dynamic hip screw (dhs) is still considered the gold standard for treating intertrochanteric fractures by many. not many studies compare the dhs with proximal femoral nail (pfn), in type ii intertrochanteric ...

متن کامل

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw (DHS).

BACKGROUND Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteric f...

متن کامل

Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures.

PURPOSE To compare the outcome in patients who underwent surgery for unstable intertrochanteric femoral fractures using the proximal femoral locking plate versus the dynamic hip screw (DHS). METHODS 15 men and 5 women aged 32 to 78 (mean, 55) years were randomised to the proximal femoral locking plate group, whereas 14 men and 6 women aged 38 to 75 (mean, 59) years were randomised to the conv...

متن کامل

Letter to the editor: Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures.

To the Editor: We read with interest the article by Dhamangaonkar et al.1 May the authors clarify the following points. 1. A dynamic hip screw (DHS) with fixed angle locking screws reduces the risk of implant failure, particularly for patients with osteoporotic bone or less stable fracture configurations.2 Why did the authors compare a proximal femoral locking plate with a non-locking 135o DHS?...

متن کامل

Comparing the Intramedullary Nailing Method Versus Dynamic Hip Screw in Treatment of Unstable Intertrochanteric Fractures

INTRODUCTION Dynamic Hip Screw fixation is currently considered as a standard treatment for pre-trochanteric fractures; however, due to the long-term hospitalization and some other complications, some researchers have proposed intramedullary nailing as the alternative surgical treatment. The aim of this study was to compare and examine the consequences of the using intramedullary nailing method...

متن کامل

Proximal Femoral Nail vs. Dynamic Hip Screw in Treatment of Intertrochanteric Fractures: A Meta-Analysis

BACKGROUND The aim of this meta-analysis was to compare the outcomes of proximal femoral nail (PFN) and dynamic hip screw (DHS) in treatment of intertrochanteric fractures. MATERIAL AND METHODS Relevant randomized or quasi-randomized controlled studies comparing the effects of PFN and DHS were searched for following the requirements of the Cochrane Library Handbook. Six eligible studies invol...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 4  شماره 1

صفحات  23- 28

تاریخ انتشار 2016-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023