Updating the Planar Patterson-Parker Table for Ir-192 and Cs-137 Brachytherapy Sources Using the Most Recent TG-43U1 Recommended Dosimetric Parameters

نویسندگان

  • A. S. Meigooni Comprehensive Cancer Center of Nevada, 3730 S. Eastern Dr., Las Vegas, NV, USA
  • M. A. Mosleh-Shirazi Center for Research in Medical Physics and Biomedical Engineering, and Department of Radiotherapy, Shiraz University of Medical Sciences, Shiraz, Iran
  • R. Faghihi Department of Medical Radiation Engineering, Shiraz University, Shiraz, Iran
  • Z. Naghshnezhad Department of Medical Radiation Engineering, Shiraz University, Shiraz, Iran
چکیده مقاله:

Background: The Patterson-Parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. These tables were created using the dosimetric data for 226Ra that was determined in air and were utilized for dose calculations around implants with Ra-equivalent radionuclides such as 137Cs and 192Ir. Therefore, the differences of the tissue attenuation and anisotropy of these radionuclides and their impact on dose uniformity of the implants were ignored. Objective: In this study, the Patterson-Parker table has been updated for 137Cs and 192Ir sources using their recent dosimetric data. Furthermore, the dose uniformity for different loading schemes, as a function of the implant area, was tested. Methods: The updated Paterson-Parker tables were generated for 137Cs and 192Ir sources using their published dosimetric parameters that have been determined following the American Association of Physicists in Medicine (AAPM) Task group 43 (TG-43U1) recommendations. The accuracies of the updated tables were examined by two independent methods, Monte Carlo simulation technique and a commercially available treatment planning system. In addition to the dose values along the central axis of the implant, dose profiles along two orthogonal directions were evaluated for the selection of the optimal radioactivity distribution in an implant. Results: We found that the original Paterson-Parker loading scheme of the radioactivity as a function of the implant size has to be adjusted to achieve the optimal dose distribution (1000 cGy ±10%) in an implant. In addition, it was shown that the same implant size for the mg-hr required for 137Cs was not identical to that of 192Ir. Similarly, there were some differences between the updated table and the published Paterson-Parkers tables. Independent Monte Carlo simulations and treatment planning data had excellent agreement with the updated data. Conclusion: The conventional version of Paterson-Parker tables are not useful for the two commonly used brachytherapy sources. The updated version of the tables should be used instead.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

updating the planar patterson-parker table for ir-192 and cs-137 brachytherapy sources using the most recent tg-43u1 recommended dosimetric parameters

background: the patterson-parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. these tables were created using the dosimetric data for 226ra that was determined in air and were utilized for dose calculations around implants with ra-equivalent radionuclides such as 137cs and 192ir. therefore, the differences of the tissue attenuation ...

متن کامل

Monte Carlo calculations and experimental measurements of the TG‐43U1‐recommended dosimetric parameters of 125I (Model IR‐Seed2) brachytherapy source

A new design of 125I (Model IR-Seed2) brachytherapy source has been manufactured recently at the Applied Radiation Research School, Nuclear Science and Technology Research Institute in Iran. The source consists of six resin beads (0.5 mm diameter) that are sealed in a cylindrical titanium capsule of 0.7 mm internal and 0.8 mm external diameters. This work aims to evaluate the dosimetric paramet...

متن کامل

Developing a Treatment Planning Software Based on TG-43U1 Formalism for Cs-137 LDR Brachytherapy

BACKGROUND The old Treatment Planning Systems (TPSs) used for intracavitary brachytherapy with Cs-137 Selectron source utilize traditional dose calculation methods, considering each source as a point source. Using such methods introduces significant errors in dose estimation. As of 1995, TG-43 is used as the main dose calculation formalism in treatment TPSs. OBJECTIVES The purpose of this stu...

متن کامل

developing a treatment planning software based on tg-43u1 formalism for cs-137 ldr brachytherapy

conclusions according to the results, the old dosimetry formalisms, overestimate the dose especially towards the applicator’s tip. while the tg-43u1 based software perform the calculations more accurately. results for a typical arrangement of 10 active pellets in the applicator, the percentage difference between doses obtained by the new algorithm at 1cm distance from the tip of the applicator ...

متن کامل

A Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation

Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

متن کامل

TG‐43U1 parameterization of elongated RadioCoil P103d brachytherapy sources

Recently, to eliminate problems associated with seed type sources, RadioMed Corporation (Tyngsboro, MA) introduced RadioCoil 103Pd sources for interstitial prostate implants. The RadioCoil sources are available in integral lengths ranging from 1.0 cm to 6.0 cm. In this project, dosimetric characteristics of these sources were determined following the TG-43U1 recommendations, with consideration ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 1

صفحات  -

تاریخ انتشار 2012-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023