Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

نویسنده

  • Mpumelelo Nyathi Department of Medical Physics Sefako Makgatho Health Sciences University SouthAfrica
چکیده مقاله:

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Spheres A, B, and C (16 mm, 12 mm, and 11 mm in diameter, respectively) attached to capillary stems were filled with technetium-99m solution (activity concentration 300 kBq/mL). They were then mounted inside a Jaszczak Phantom forming a V-shaped structure. The phantom was then filled with distilled water. Two-dimensional (2D) projections were acquired on 128 128 pixels using a Siemens E-Cam dual-head gamma camera. The Parzen, Shepp-Logan, Low Pass Cosine filters (cut-off frequencies: 0.2-0.9), and Butterworth filter (order: 1-9; cut-off frequencies: 0.3-0.9) were employed during FBP reconstruction. The line command of ImageJ software was used to draw the point spread functions of acquired 2D transaxial central slices and for the measurement of their full-width at half-maximum (FWHM). Results:The FWHM of 2D central image slices of spheres A, B, and C reconstructed using a Butterworth filter measured 20, 20, and 10 pixels, respectively. In comparison, the reconstructed images using the Parzen, Low Pass Cosine, and Shepp-Logan filters measured to 27, 25 and, 22 pixels for sphere A, 24, 22, 20 pixels for B, and 22, 20, 18 pixels for C, respectively. Conclusion: The low-pass filters successfully suppressed noise during the FBP reconstruction of SPECT images of small structures. Accordingly, the Butterworth is a suitable choice.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

the effect of e-64 on the developmental competence of sheep cocs during in vitro maturation

in the present study, the effect of e-64 at different concentrations (0.5, 1, 5 and 10 µm) added to (1) the ivm medium on oocyte nuclear maturation and developmental competence of ovine oocytes, and (2) to the ivc medium on embryonic development of ovine embryos were investigated.

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography

A filtered backprojection reconstruction algorithm was developed for cardiac single photon emission computed tomography with cone-beam geometry. The algorithm reconstructs cone-beam projections collected from ;short scan' acquisitions of a detector traversing a noncircular planar orbit. Since the algorithm does not correct for photon attenuation, it is designed to reconstruct data collected ove...

متن کامل

Time-varying reconstruction in single photon emission computed tomography

We propose a new method for reconstruction of images in single photon emission computed tomography (SPECT), when the activity distribution of the object is time-varying. The activity evolution is modeled with the first-order Markov model, and linear observation model is used to characterize the measurement system. The state-space representation of the measurement sequence reduces to an ill-cond...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 4

صفحات  300- 306

تاریخ انتشار 2019-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023