نتایج جستجو برای: Transient response

تعداد نتایج: 1083619  

Journal: :IEEJ Transactions on Electronics, Information and Systems 1995

This paper presents analytical solutions and simulations for pressure transient behavior of the partially penetrating wells (PPWs). The Newman’s product method was adopted to develop the basic instantaneous source functions which characterize the response of PPWs. These results were obtained based on the solution of fully penetrating wells (FPWs) and they were presented in Laplace domain. Furth...

Journal: :acta medica iranica 0
mohammad hossein baradaranfar department of otolaryngology, head and neck surgery, shahid sadoughi university of medical sciences, yazd, iran. saeid atighechi department of otolaryngology, head and neck surgery, shahid sadoughi university of medical sciences, yazd, iran. mohammad hossein dadgarnia department of otolaryngology, head and neck surgery, shahid sadoughi university of medical sciences, yazd, iran. rozita jafari department of otolaryngology, head and neck surgery, shahid sadoughi university of medical sciences, yazd, iran ghasem karimi department of otolaryngology, head and neck surgery, shahid sadoughi university of medical sciences, yazd, iran. abolfazl mollasadeghi department of audiology, shahid sadoughi university of medical sciences, yazd, iran.

hyperbilirubinemia at neonatal period is one of the major deteriorating factors of the auditory system. if left untreated, it may cause certain cerebral damage. this study aims to evaluate the impact of hyperbilirubinemia on the hearing of neonate. this study was conducted on 35 newborn babies with jaundice (bilirubin more than 20 mg/dl). auditory brainstem response (abr) and transient evoked o...

2005
Sheba Devan Venkat R. Subramanian Ralph E. White

An analytical expression is presented for the voltage response including the transient voltage for a simple ~i.e., no concentration gradients! porous electrode model subject to a sinusoidal input current density. The transient voltage response as a function of the frequency, exchange current density, and double layer capacitance is studied independent of the periodic ~steady state! voltage resp...

Journal: :British journal of anaesthesia 1998
G Cavill E J Simpson R P Mahajan

The transient hyperaemic response in the middle cerebral artery blood flow velocity on the release of brief compression of the ipsilateral common carotid artery has been validated as an indicator of cerebral autoregulation. We evaluated, in three stages, the effect of experimental factors such as duration of compression of the common carotid artery and magnitude of the decrease in blood flow ve...

Journal: :acta medica iranica 0
massoud ghasemi research center of endovascular intervention, tehran, iran. maryam mehrpooya department of cardiology, imam khomeini hospital complex, tehran university of medical sciences, tehran, iran. and department of cardiology, school of medicine, tehran university of medical sciences, tehran, iran. farshad ghasemi mount sini hospital, university of toronto, toronto, canada. fatemeh shahbazi department of biology, payame noor university, tehran, iran.

our aim was to report techniques and our experience in one-stage angioplasty and stenting of ostium of left common carotid and left internal carotid arteries in an octogenarian man with transient ischemic attack, who was completely recovered from neurologic insults short time after the procedure. an 81-year-old man presented with a transient ischemic attack. neurologic examination showed left s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید