temperature dependence

نویسندگان

  • J. R. Goodwin
  • V. V. Golovko
  • V. E. Iacob
چکیده

This experiment was undertaken to investigate whether the half life of the β-decay of Au in a metallic environment showed any dependence on temperature as had been claimed in a recent publication [1]. An article describing this experiment has already been published [2]. Previous publications claiming to observe a temperature dependence of β-decay half-lives [1, 3, 4] have invoked the so-called “Debye effect” to explain the phenomenon. Their authors’ explanation proceeds as follows: Beta decay involves either the emission of a positron or an electron from the nucleus, or the capture of an electron into the nucleus. Since metals possess large numbers of “conduction” electrons that are basically free to travel within the metal, these electrons are deemed to form a sort of plasma, which is referred to as a “Debye plasma”. When a beta-decaying nuclide is placed in a metallic environment, the authors propose that the presence of the Debye plasma alters the phase space available for beta decay. In the case of β-decay or electron capture decay, they argue that the available phase space is reduced, slowing the decay rate and increasing the half-life. For the case of β-decay, the available phase space is increased, having the opposite effect. According to their formulation of this theory, the change in phase space can be enhanced if the host metal is cooled to very low temperatures (e.g., ~20 K). With an eye to testing both the claimed experimental observation and the model that it generated, we have repeated one of the experiments that claimed to have observed a temperature-dependent effect [1]: a measurement of Au in gold metal. Our experiment was performed to a precision of 0.04%, more precise than the previous work by a factor of 25. We used gold samples obtained from Goodfellow Corp; these were 10 mm in diameter, 0.1 mm thick, and had a purity of 99.99+%. The foils were activated at a flux of ~10 neutrons/cm·s, each for 10 s, at the Texas A&M Triga reactor. An activated gold sample, now containing Au, was placed on the cold head of a CryoTorr 7 cryopump. A 70% HPGe detector was placed directly opposite the sample, and just outside the plate covering the cryopump. A cavity had been bored in the cover-plate such that only 3.5 mm of stainless steel remained between the sample and the face of the detector. We used the same set-up for measurements at both room temp and at 20 K, the distance between the detector face and the sample being 4.5 cm. Consecutive six-hour-long γ-ray spectra, were acquired and saved consecutively, for a period of about one month for each temperature. All spectra were collected for an identical, pre-set live time. Throughout the experiment, we synchronized the time prior to each day’s collection, using the signal broadcast from radio station WWVB. We also kept the system’s dead time below about 3% for all but the first few spectra. Since the TRUMP card used in our data collection corrects for dead time losses, our results were nearly independent of dead time losses. However, to achieve a precision under 0.1%, we performed an additional procedure to allow us to determine the presence of any residual, rate-dependent effects. This procedure involved measuring the 662 keV γ-ray peak from a Cs source, then repeatedly re-measuring this peak in the presence of a Ba source, which was moved nearer and nearer the detector. As the barium source moved closer to the detector, the dead time and the number of chance coincidences

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring the temperature dependence of refractive index in water phantom for precise monitoring of the absorbed dose by radiation therapy techniques

In this paper, an experimental setup is used to measure the temperature dependence of the refractive index of a water phantom. In radiation calorimetry by laser beams and interferometric systems, the amount of change induced by radiation within the phantom can be accurately measured. Absorption of dose and the resulted change in temperature changes the refractive index within the material. In o...

متن کامل

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Temperature dependence of continuum and time resolved photoluminescence of germanium nanostructures

  Germanium nanostructures were generated in the post annealed germanium oxide thin films. Visible and near infrared photoluminescence bands were observed in the samples annealed at 350°C and 400°C, respectively. These different luminescence ranges are attributed to the presence of the defects in oxide matrix and quantum confinement effect in the germanium nanostructures, respectively. Decay ti...

متن کامل

Representation of the temperature nano-sensors via cylindrical gate-all-around Si-NW-FET

In this paper, the temperature dependence of some characteristics of cylindrical gate-all-around Si nanowire field effect transistor (GAA-Si-NWFET) is investigated to representing the temperature nano-sensor structures and improving their performance. Firstly, we calculate the temperature sensitivity of drain-source current versus the gate-source voltage of GAA-Si-NWFET to propose the temperatu...

متن کامل

Representation of the temperature nano-sensors via cylindrical gate-all-around Si-NW-FET

In this paper, the temperature dependence of some characteristics of cylindrical gate-all-around Si nanowire field effect transistor (GAA-Si-NWFET) is investigated to representing the temperature nano-sensor structures and improving their performance. Firstly, we calculate the temperature sensitivity of drain-source current versus the gate-source voltage of GAA-Si-NWFET to propose the temperatu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008