 A novel approach to automatic position calibration for pixelated crystals in gamma imaging

نویسندگان

  • Hadi Khanmohammadi Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
  • Hamid Sabet Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, USA
  • Mohammad Reza Ay Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran|Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
  • Navid Zeraatkar Department of Radiology, University of Massachusetts Medical School, Worcester, MA, USA
  • Saeed Sarkar Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran, Iran
  • Salar Sajedi Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
  • Sanaz Kaviani Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
چکیده مقاله:

Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we present a novel approach to automatically calibrate pixelated crystal array position estimation. Methods: In the flood image of a pixelated crystal array the local peaks represent the estimation of position for the gamma photons that interacted in a single crystal pixel. First, the method detects 2-D peak locations automatically in the case of blurred pixel responses in the presence of noise and disturbance of the image. The algorithm consists of a filtering step for smoothing the image followed by two rounds of local peak detection. After localizing image peaks, the correction routine will map the image locations to the crystal pixels using the thin-plate spline interpolation method. Results:The algorithm is tested for two flood images obtained from developed detector with different irregularity levels. By configuring constant parameters according to the detector configuration the method detected all crystal pixels in the image and map them correctly. The method further has been tested for10 identical blocks and the result showed automatic peak detection routine for all the blocks. Conclusion: An automatic peak detection is presented to work instead of time consuming manual calibration routines. The method shows robust performance in the presence of image noise.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

new approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

introduction:surgeosight is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (sln) imaging in the operation room. like conventional gamma cameras it is necessary to calibrate surgeosight for linearity distortion, ener...

متن کامل

a new approach to credibility premium for zero-inflated poisson models for panel data

هدف اصلی از این تحقیق به دست آوردن و مقایسه حق بیمه باورمندی در مدل های شمارشی گزارش نشده برای داده های طولی می باشد. در این تحقیق حق بیمه های پبش گویی بر اساس توابع ضرر مربع خطا و نمایی محاسبه شده و با هم مقایسه می شود. تمایل به گرفتن پاداش و جایزه یکی از دلایل مهم برای گزارش ندادن تصادفات می باشد و افراد برای استفاده از تخفیف اغلب از گزارش تصادفات با هزینه پائین خودداری می کنند، در این تحقیق ...

15 صفحه اول

a benchmarking approach to optimal asset allocation for insurers and pension funds

uncertainty in the financial market will be driven by underlying brownian motions, while the assets are assumed to be general stochastic processes adapted to the filtration of the brownian motions. the goal of this study is to calculate the accumulated wealth in order to optimize the expected terminal value using a suitable utility function. this thesis introduced the lim-wong’s benchmark fun...

15 صفحه اول

Investigation on optical properties in the surface of KClxBr1-x mixed crystals irradiated to gamma radiation (A new approach)

Background: Similar to the thermoluminescence (TL) spectra, the optical parameters variations can also be used in TL crystals for dosimetry purposes. These optical parameters can include absorption, transmission and reflection coefficients. Materials and Methods: Single crystals of KBr and KCl which have been used in this research were grown from laboratory grade extra pure precursor p...

متن کامل

a novel method based on learning automata for automatic lesion detection in breast magnetic resonance imaging

breast cancer continues to be a significant public health problem in the world. early detection is the key for improving breast cancer prognosis. in this way, magnetic resonance imaging (mri) is emerging as a powerful tool for the detection of breast cancer. breast mri presently has two major challenges. first, its specificity is relatively poor, and it detects many false positives (fps). secon...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 27  شماره 2

صفحات  106- 112

تاریخ انتشار 2019-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023