Comparing Fracture Resistance of Endodontically Treated Teeth Using Different Preparation-Obturation Combinations

نویسندگان

  • Akam Saeidi Assistant Professor, Department of Endodontics, Faculty of Dentistry, Babol University of Medical Sciences, Babol, Iran
  • Ali Bijani Assistant Professor, Social Determinant of Health Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran
  • Azadeh Hesarkhani Assistant Professor, Department of Endodontics, Faculty of Dentistry, Kashan University of Medical Sciences, Kashan, Iran
  • Hanif Allahbakhshi Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Kashan University of Medical Sciences, Kashan, Iran
  • Zahra Sadat Madani Assistant Professor, Department of Endodontics, Faculty of Dentistry, Babol University of Medical Sciences, Babol, Iran
چکیده مقاله:

Background:One of the main reasons for extraction of endodontically treated teeth is vertical root fracture (VRF). Some factors such as root canal treatment are involved in vertical root fracture because of their potential to weaken the tooth structure. Therefore, this study aimed to investigate the effect of combining different obturation materials and rotary systems on the fracture resistance of treated teeth. Methods:Eighty extracted maxillary central incisors were selected. The coronal portions of all teeth wereremoved at the cemento-enamel junction leaving the root segment of nearly 13 mm length. Roots were randomly divided into2 groups according to the system used in root canal preparations, Group I: ProTaper, Group II: Wave 1. Each main group was further subdivided into 2 equal subgroups according to the obturation system being used, Subgroup A: ProTaper, AH26 obturator, Subgroup B: ProTaper, Bioceramic, Subgroup C: Wave 1, AH26 obturator and Subgroup D: Wave 1, Bioceramic. Fracture resistance of each sample was measured by loading in universal testing machine. The results were analyzed with two-way ANOVA followed by multiple comparison Tukey HSD test. Results: The highest mean fracture resistance value (256.7N) was associated with Soft-Core/AH26 obturation and wave one (subgroup C), while the lowest value (239.8 N) was for Bioceramic sealer and Wave 1 (subgroup D); however, there was no statistical significant difference (P>0.05) among all tested subgroups. Conclusion: All instrumentation techniques caused weakening of the root structure and made them susceptible to fracture without any significant difference and therefore alternative strategies should be considered to reinforce endodontically treated roots.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a comparison of the fracture resistance of endodontically treated teeth using three different post systems

statement of problem: it is yet unclear whether fiber-reinforced composite posts can enhance the mechanical properties and prevent vertical fractures of teeth under chewing loads. purpose: the purpose of this study was to compare the fracture resistance and failure mode of endodontically treated teeth restored with three different post systems. materials and methods: thirty-six maxillary canine...

متن کامل

Effect of Different Instrumentation Techniques on Vertical Root Fracture Resistance of Endodontically Treated Teeth

STATEMENT OF THE PROBLEM Vertical root fractures are catastrophic events that often result in tooth extraction. Many contributing factor are associated with increasing incidence of vertical root fracture. Root canal preparation is one of the predisposing factors which can increase the root susceptibility to vertical fracture. PURPOSE The aim of this study was to compare the effects of three d...

متن کامل

Fracture resistance of endodontically treated teeth restored by different FRC posts: an in vitro study.

BACKGROUND Posts and cores are often required for restoration of pulpless teeth and to provide retention and resistance for a complete crown, but conventional posts may increase the root fracture. OBJECTIVE This study was performed to compare the root fracture resistance of extracted teeth treated with different fibers reinforced with composite posts and treated teeth with conventional post a...

متن کامل

An in vitro Evaluation of Fracture Resistance of endodontically treated Teeth with Different Restorative Materials.

AIMS The aim of the present study is to compare and assess the fracture resistance of root canal treated teeth with different restorative materials. MATERIALS AND METHODS The present in vitro study was carried out on seventy-five freshly extracted, noncarious, single-canal human lower-first premolars with similar anatomic characteristics. Teeth were randomly assigned to five groups with 15 te...

متن کامل

Comparison of fracture resistance of endodontically treated teeth restored with two different fiber posts

Background: The aim of this study was to determine and compare the fracture resistance of endodontically treated teeth restored with two different glass fiber posts. Materials and methods: Thirty extracted intact human premolar teeth were selected for the study. All the teeth were decoronated maintaining root length of 15mm from apex. Root canals were enlarged using protaper rotary file. Obtura...

متن کامل

Effect of Different Luting Cements on Fracture Resistance in Endodontically Treated Teeth

INTRODUCTION The aim of the present study was to evaluate the effect of three types of luting cements used for post cementation on the fracture resistance of endodontically treated maxillary premolars, restored with resin composite. MATERIALS AND METHODS One hundred intact single-rooted human maxillary premolars were randomly divided into 5 groups of 20 each. In groups 2-5, post spaces were p...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 26  شماره 4

صفحات  280- 288

تاریخ انتشار 2019-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023