Designing CT scanning rooms and estimating patient and personnel absorbed dose using code (MCNPX 2.6)

نویسندگان

چکیده مقاله:

One of the most widely used diagnostic devices in medical imaging is computed tomography scanning with the use of X-ray ionization. After years of using this tool in the diagnosis and treatment, external doses of these beams can pose a risk of secondary cancer, which is significant in terms of radiation safety and protection. In this paper, using the Monte Carlo code MCNPX2.6 performed over three phases, a 40-years-old male MIRD and CT room was designed and simulated at different locations of the CT room and the absorbed dose rate was calculated. In the first phase, by calculating and simulating, the mean absorption dose rate was obtained and then the safe and unsafe locations were identified. In the second step, by analyzing the results, the highest mean dose rate of the phantom absorption dose was obtained in the simulation of abdominal area scans and its internal organs. In the third stage of this article, by designing a lead shield, a solution was proposed to reduce the effectiveness of absorptive doses that could improve the safety level.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Iodine-131 Absorbed Dose and Technetium-99m in Thyroid Scanning Using the MCNPX Simulation Code in the ORNL-MIRD Phantom

Thyroid scanning is performed to examine the thyroid gland disorders using 99mTc. Through the obtained images can evaluate the size of the thyroid gland, the amount of its removal compared with the salivary gland, examine the thyroid nodules and its performance impairments. According to the scan view, it is possible to differentiate between hot and cold thyroid nodules that need different thera...

متن کامل

Evaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)

Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...

متن کامل

Comparison of I-131, I-123 Absorbed Dose and Tc-99m in Thyroid Scanning Using MCNP Code in ORNL-MIRD Phantom

Introduction: Thyroid cancer is at the ninth from ten of common malignant cancer. A man has higher risk to get Thyroid cancer that a woman has. This organ is lain near human neck. The use of radioactive I-131, I-123 and Tc-99m for diagnosis of thyroid cancer has a risk where other organs around Thyroid will accept dose of radiation. One of the risks is large dose which is accep...

متن کامل

Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT

Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE...

متن کامل

Patient absorbed dose comparison in CT and Stereoradiography (EOS) imaging during lower limb torsion evaluation using in-vivo and in-vitro dosimetry methods

Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...

متن کامل

Simulation of the BNCT of Brain Tumors Using MCNP Code: Beam Designing and Dose Evaluation

Introduction BNCT is an effective method to destroy brain tumoral cells while sparing the healthy tissues. The recommended flux for epithermal neutrons is 109 n/cm2s, which has the most effectiveness on deep-seated tumors. In this paper, it is indicated that using D-T neutron source and optimizing of Beam Shaping Assembly (BSA) leads to treating brain tumors in a reasonable time where all IAEA ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 7  شماره 3

صفحات  41- 49

تاریخ انتشار 2019-09

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023