Effect of Wind on Thermal Performance of Heller Dry Cooling Tower

نویسندگان

  • Foad Farhani Assistant Professor, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
  • Mohammad Ali Ardekani Associate Professor, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
  • Mohsen Mazidi Instructor, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
چکیده مقاله:

In a steam power plant, the temperature of the cooling water leaving the condenser for recyclingshould decrease. This is achieved in a cooling tower. The Heller cooling tower does not require waterfor operation, thus, it is a suitable system for use in thermal power plants throughout Iran. Wind is anenvironmental factor that unfavorably affects the performance of a cooling tower. Previous studieshave not considered real prevailing conditions appropriately; their conclusions are incomplete and, attimes, contradictory. The present field study of the cooling tower at Montazer-Ghaem Power Plant inthe city of Karaj in Iran investigated the effect of wind on the thermal performance of the coolingtower. Wind velocity was measured using blade-and-cup type digital anemometers. The direction ofthe wind around the cooling tower was determined using tufts. Ultrasonic flow meters and resistancethermometers were used to measure the flow rates and temperatures of the water at the inlet and outlet,respectively. Results show that, despite air suction, no separation occurred at the periphery of thecooling tower. The front cooling sectors that face the wind and the back sectors that do not directlyface the wind were more thermally efficient. They transferred about 60% more heat than did thecooling sectors parallel to the wind direction at the periphery of the cooling tower. The results alsoshowed that thermal performance in the front and back cooling sectors increased as the wind velocityincreased and that in the peripheral sectors decreased.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

effect of wind on thermal performance of heller dry cooling tower

in a steam power plant, the temperature of the cooling water leaving the condenser for recyclingshould decrease. this is achieved in a cooling tower. the heller cooling tower does not require waterfor operation, thus, it is a suitable system for use in thermal power plants throughout iran. wind is anenvironmental factor that unfavorably affects the performance of a cooling tower. previous studi...

متن کامل

Study of Degradation of Dry Cooling Tower Performance under Wind Conditions and Method for Tower Efficiency Enhancement (RESEARCH NOTE)

Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...

متن کامل

effect of oral presentation on development of l2 learners grammar

this experimental study has been conducted to test the effect of oral presentation on the development of l2 learners grammar. but this oral presentation is not merely a deductive instruction of grammatical points, in this presentation two hypotheses of krashen (input and low filter hypotheses), stevicks viewpoints on grammar explanation and correction and widdowsons opinion on limited use of l1...

15 صفحه اول

the effect of task complexity on efl learners’ written task performance in terms of accuracy and complexity

هدف اصلی این تحقیق بررسی تاثیر افزایش میزان پیچیدگی تکالیف مکالمه محور بر دقت و صحت و پیچیدگی عملکرد نوشتاری زبان آموزان می باشد. بدین منظور، 50 نفر از دانش آموزان دختر در رده ی سنی 15 الی 18 سال درسطح pre-intermediate از طریق petو vhs تست به عنوان شرکت کنندگان در تحقیق انتخاب شدند و به دو گروه آزمایشی و کنترل بصورت اتفاقی تقسیم شدند. اعضای گروه آزمایشی دو تکلیف ساده و پیچیده را طی 2 جلسه انجام...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 45  شماره 1

صفحات  1- 8

تاریخ انتشار 2014-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023