Humic acid removal from aqueous solutions by peroxi-electrocoagulation process

نویسندگان

  • Ahmad Reza Yazdanbakhsh Department of Environmental Health Engineering, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Amir Sheikhmohammadi Department of Environmental Health Engineering, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Ehsan Aghayani Department of Environmental Health Engineering, Tarbiat Modares University of Medical Sciences, Tehran, Iran
  • Majid Kermani Department of Environmental Health Engineering, Iran University of Medical Sciences, Tehran, Iran
  • Sanaz Komasi Department of Environmental Engineering, Islamic Azad University, West Tehran Branch, Tehran, Iran
چکیده مقاله:

Background: Natural organic matter is the cause of many problems associated with water treatment such as the presence of disinfection by-products (DBPs) and membrane fouling during water filtration. In this study, the performance of the peroxi-electrocoagulation process (PEP) was investigated for the removal of humic acids (HAs) from aqueous solutions. Methods: PEP was carried out for the removal of HA using a plexiglas reactor with a volume of 2 L and fitted with iron electrodes and a direct current supply (DC). Samples were taken at various amounts of pH (2-4), current density (1 and 2A/cm2), hydrogen peroxide (50-150 mg/L) and reaction time (5-20 minutes) and then filtered to remove sludge formed during reaction. Finally, the HA concentration was measured by UV absorbance at 254 nm (UV254). Results: Results indicated that increasing the concentration of H2O2 from 50 to 150 mg/L increased HA removal efficiency from 83% to 94.5%. The highest removal efficiency was observed at pH 3.0 by increasing the pH to the alkaline range, the efficiency of the process was reduced. It was found that HA removal efficiency was high in current density 1A/cm2. Increasing current density up to 1 A cm-2 caused a decrease in removal efficiency. Results of this study showed that under the optimum operating range for the process ([current density] = 1A/cm2, [hydrogen peroxide concentration] = 150 mg/L, [reaction time]= 20 minutes and [pH]= 3.0), HA removal efficiency reached 98%. Conclusion: It can be concluded that PEP has the potential to be utilized for cost-effective removal of HA from aqueous solutions. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

humic acid removal from aqueous solutions by peroxi-electrocoagulation process

background: natural organic matter is the cause of many problems associated with water treatment such as the presence of disinfection by-products (dbps) and membrane fouling during water filtration. in this study, the performance of the peroxi-electrocoagulation process (pep) was investigated for the removal of humic acids (has) from aqueous solutions. methods: pep was carried out for the remov...

متن کامل

Removal of natural organic matter from aqueous solutions by electrocoagulation

Natural organic matter (NOM) affects some qualitative parameters of water such as color. In addition, it can deteriorate the performance of water treatment process including coagulation, adsorption, and membranes. NOM also reacts with chlorine in the chlorination process and may form disinfection by-products. The present study was carried out in laboratory-scale in a batch system using a cylind...

متن کامل

Application of Electron Beam/MnII Process for Humic Acid Removal from Aqueous Solutions

Introduction: Natural organic matters (NOMs) existing in water resources led to various problems such as formation of disinfectant by-products (DBPs). Humic matters like humic acid (HA) are component of NOMs that should be removed from water. Advanced oxidation process (AOPs) is one of the NOMs removal methods. The aim of this study was to survey the degradation of humic acid by electron beam i...

متن کامل

Investigation of Phenol Removal by Proxy-Electrocoagulation Process with Iron Electrodes from Aqueous Solutions

Background: Phenol as an aromatic hydroxyl compound are considered as a priority pollutant.  Because of their stability, solubility in water and high toxicity had health important. Methods: In the present experimental study, electrocoagulation reactor by iron electrodes are used in the presence of hydrogen peroxide to phenol removing from aqueous solutions. Effects of variables including ...

متن کامل

Removal of textile dye from aqueous solutions by nanofiltration process

The feasibility of employing nanofiltration (NF) in the decolorization of ionic (direct blue 86) and nonionic (disperse blue 56) dye aqueous solutions was investigated. The effects of feed concentration (60- 180 mg/l), pressure (0.5- 1.1 MPa) and pH (6- 10) were studied. Experiments were performed in a laboratory- scale set up by using a TFC commercial spiral wound polyamide nanofilter. The res...

متن کامل

application of electron beam/mnii process for humic acid removal from aqueous solutions

introduction: natural organic matters (noms) existing in water resources led to various problems such as formation of disinfectant by-products (dbps). humic matters like humic acid (ha) are component of noms that should be removed from water. advanced oxidation process (aops) is one of the noms removal methods. the aim of this study was to survey the degradation of humic acid by electron beam i...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره None

صفحات  53- 58

تاریخ انتشار 2015-06

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023