Measurement of absorbed dose in normoxic polymer gel and study of gold nanoparticles configuration effects

نویسندگان

چکیده مقاله:

Radiotherapy includes all methods that can deliver a particular amount of ionizing radiation to malignant tissues, assuming that minimal damage hurts healthy tissues. We are looking for a valuable and reliable method to measure absorbed dose and the ability to measure the distribution of absorbed dose in three dimensions which nowadays is one of the three-dimensional dosimetry methods in using radiation-sensitive polymer gels. The purpose of the present study was to calculate the amount of increase of absorbed dose in the presence of gold nanoparticles and to investigate the type of gold nanoparticles arrangement (uniformly and shells) in the polymer gel of normoxic. In this study from both experimental and simulation approaches, a dosimeter of a normoxic polymer type gel was used to measure the amount of absorbed dose changes of Gamma rays in the presence of gold nanoparticles irradiated with   Iridium-192 source beams. Thermolominans dosimetry reading system was used to read steps of dose value and then    MCNPX computational code was simulated by using Monte Carlo method. The results were compared and investigated by experimental experiments. In the presence of gold nanoparticles uniformly distributed in polymer gel, with 0.1mM to 1.5mM, the maximum absorbed dose was 0.24% and in shell state it was 20%. The result and investigation of both experimental and simulation studies showed that the optimum density of gold nanoparticles in the normoxic polymer gel is 1.5mM, which can be used for clinical trials.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increased Absorption Dose with the Presence of Gold Nano particles in a Normoxic Polymer Gel: Method Monte Carlo

Introduction: Radiotherapy involves all methods that can provide a special amount of ionizing radiation to malignant tissue with the assumption that minimal damage to healthy tissues is achieved. We are looking for a valuable and reliable method to measure the absorption dose and also the ability to measure the absorption dose distribution in three dimensions, which today is th...

متن کامل

Effect of gold nanoparticles on dose enhancement of 6 Mv X-rayin MAGIC_f polymer gel dosimeter

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...

متن کامل

Dose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...

متن کامل

dose enhancement effect of gold nanoparticles on magica polymer gel in mega voltage radiation therapy

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. material and methods: in this study...

متن کامل

a contrastive study of rhetorical functions of citation in iranian and international elt scopus journals

writing an academic article requires the researchers to provide support for their works by learning how to cite the works of others. various studies regarding the analysis of citation in m.a theses have been done, while little work has been done on comparison of citations among elt scopus journal articles, and so the dearth of research in this area demands for further investigation into citatio...

Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry

Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 7  شماره 2

صفحات  35- 42

تاریخ انتشار 2019-06

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023