Primary efforts to optimize image quality in chest direct digital radiography of pediatric patient (for the age group 0 to 1 and 1 to 5 years) with survey some effective parameters in image quality and patient dose

نویسندگان

  • Behzad Mohsenzadeh Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran
  • Fereshte Rahmani Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran
  • Hamed Bagheri Radiation & wave research center Aja University of Medical Sciences
  • Khatereh Shamsi MSc in radiobiology Department of Medical Physics Babol University of Medical Sciences
  • Leila Azimi Departeman of imaging, Velayat hospital, University of medical science, Qazvin, Iran
  • Mohammad Reza Deevband Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iran TEL: 09123044609, E-mail: [email protected]
  • Zeinab Kaveh Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran
چکیده مقاله:

Introduction: This study, evaluate pediatric digital radiography. Due to the high rates of this test and the high sensitivity of children to ionizing radiation in comparison with adults, it is attempted to achieve near optimal conditions by reducing the dose and maintaining the image quality. The object of the study is to change the irradiation parameters such as kV and mA and change them to a point where the dose is as high as possible for improved image quality or image quality preservation. Materials and Methods: Irradiation data from 50 children were collected for each of 2 age groups 0-1and 1-5 years old, and the mean values of voltage, current, and tube-to-table distance were obtained. To investigate Improving image quality as the dose reduced, a homogeneous phantom was constructed to produce an equivalent chest distribution with less than 5% accuracy. The Monte Carlo simulation and the equivalent human phantom ORNL were used to make this phantom. Then, with use of a digital radiographic system and dosimetric instruments that calculate the dose, the dose of homogeneous phantom was measured. Subsequently, irradiation parameters such as kV and current were changed to provide voltages higher than reference voltage and lower current flow rates than those referring to a dose lower than the reference dose, the choice of these conditions is due to the decrease in absorption dose. Finally, three parameters MTF, SNR and CNR are measured using the tools designed in this phantom. Results: With the results obtained for three parameters of each of the two age groups, the result was that for the age group 0-1, the best selection for the voltage and current was 60 and 2.5, respectively, in which the dose reduced and image quality increased. For 1 -5 years the voltage 75 with a current range of 3.2 to 5 mAs was close to optimum. Conclusion: This article has determined wide variations in radiation dose of x-ray examinations. Also, to Reduce patient dose and enhance image quality is suggested following solutions: 1-               utilization of Automatic Exposure Control (Of course, it's not easy to use for children with small body) 2-               Used additional filters such as copper: This filter by removing low-energy beam makes the beam harder, and photoelectric effect reduced, as a result, the patient dose is reduced. The works that was done in this study: Improving the exposure parameter compared to dose reference extracted 50 images for each age group and as well as improved its image quality.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

investigating cda tendency and critical thinking abilities of iranian translation students in relation to their translation quality

امروزه مسئله ی اساسی در رویکرد های جدید زبانشناسی، ابعاد اجتماعی و ایدئولوژیک زبان تلقی می شود. گروه های مختلف اجتماعی، سیاسی و یا مذهبی از زبان به عنوان ابزاری برای دستیابی به اهداف درون گروهی خود استفاده می کنند (ون دایک، 2003). آنها معولا ایدئولوژی خود را صریحا ابراز نمی کنند بلکه آن را در غالب کلمات و ساختارهای زبانی پنهان نگه می دارند. تشخیص ایدئولوژی های پنهان در گفتمان نیازمند این موضوع ...

efficacy of increasing focus to film distance (ffd) for patient’s dose and image quality in pediatric chest radiography

background: increasing the x-ray focus to film distance (ffd) has been advocated as an effective method to reduce the patients’ radiation dose. the aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.material and methods: sixty pediatric patients were x-ray imaged at ffds of 100 and 130 cm. dose measurements were ...

متن کامل

construction and validation of translation metacognitive strategy questionnaire and its application to translation quality

like any other learning activity, translation is a problem solving activity which involves executing parallel cognitive processes. the ability to think about these higher processes, plan, organize, monitor and evaluate the most influential executive cognitive processes is what flavell (1975) called “metacognition” which encompasses raising awareness of mental processes as well as using effectiv...

Dose Reduction to the Thyroid Gland in Pediatric Chest Radiography

Background  It is remain a main concern that pediatric chest radiographies contribute to the significant radiation exposure to the thyroid gland as a more susceptible organ to radiation induced cancer. The aim of this study was to evaluate the entrance surface dose (ESD) of pediatric chest radiography compared to the diagnostic reference levels (DRL) and evaluation the efficacy of the lead (Pb)...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  416- 416

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023