Quality Control Assessment of Conventional Radiology Devices in Iran

نویسندگان

  • Ali Ebrahiminia Assistant professor of medical physics, Biochemistry and Medical Physics Dept., School of Medicine, Guilan University of Medical Sciences, Rasht, Iran
  • Masoumeh Giahi Student of Radiology Technology, Department of Radiology Technology, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
  • Mohsen Asadinezhad Department of Radiology Technology, School of Paramedical Sciences, Mashhad University of Medical Sciences
چکیده مقاله:

Introduction Quality control (QC) techniques are used in monitoring and maintenance of the components of an x-ray system. QC of radiology devices plays a significant role in reduction of medication dose and optimization of image quality. This study aimed to conduct QC tests on randomly selected radiology devices, installed in diagnostic imaging departments of Iran. Materials and Methods In total, quality control tests were conducted on 51 conventional radiology devices installed in 20 cities of Iran in order to assess the accuracy of peak kilovoltage  (kVp), exposure time, exposure linearity and reciprocity, reproducibility of exposure and determination of half-value layer (HVL) using a calibrated Mult-O-Meter. Results In this study, 38.6% of devices had intolerable variance of kVp accuracy. The results of 34.5% of devices were out of the acceptable limits in exposure time accuracy test. In 46.7% and 53.1% of devices, variance was greater than the acceptable range for exposure linearity and exposure reciprocity, respectively. In terms of reproducibility of exposure test, the reproducibility variance and percentage of tube output variations in 19.4% of devices exceeded the limits. Moreover, the thickness of first HVL was lower than the acceptable limit in 14.7% of devices. Conclusion According to the results of this study, there were wide variations in QC test results, perhaps mainly due to the fact that it is not an obligation to implement QC programs in Iran. The most important problems were non-reciprocity of exposure, nonlinearity of exposure with milliampere-second (mAs), kVp and timer inaccuracy. Involvement of medical physicists, radiologists and radiographers in the implementation of QC programs at various stages of development, installation and use of equipment should enable the gradual improvement in equipment performance.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

quality control assessment of conventional radiology devices in iran

introduction quality control (qc) techniques are used in monitoring and maintenance of the components of an x-ray system. qc of radiology devices plays a significant role in reduction of medication dose and optimization of image quality. this study aimed to conduct qc tests on randomly selected radiology devices, installed in diagnostic imaging departments of iran. materials and methods in tota...

متن کامل

Quality Control Assessment of Radiology Devices in Kerman Province, Iran

Introduction Application of quality control (QC) programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests...

متن کامل

Quality Control of Conventional Radiology Devices in Selected Hospitals of Khuzestan Province, Iran

Introduction Quality control techniques used to test the components of the radiological system and verify that the equipment is operating satisfactorily. In this study, quality control (QC) assessment of conventional radiology devices was performed in frequently visited radiology centers of Khuzestan province, Iran. Materials and Methods Fifteen conventional radiology devices were examined, bas...

متن کامل

quality control of conventional radiology devices in selected hospitals of khuzestan province, iran

introduction quality control techniques used to test the components of the radiological system and verify that the equipment is operating satisfactorily. in this study, quality control (qc) assessment of conventional radiology devices was performed in frequently visited radiology centers of khuzestan province, iran. materials and methods fifteen conventional radiology devices were examined, bas...

متن کامل

Quality control of radiology devices in Health Centers Affiliated with Hormozgan University of Medical Sciences

Introduction: Regular quality control of radiology devices and fixing their defects can play a crucial role in reducing absorbed dose of patients, increasing their longevity, and improving the quality of radiographic images. This study was aimed at performing quality control according to the standards and features of radiology machines in the teaching hospitals of Hormozgan Province. Methods: S...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 14  شماره 1

صفحات  1- 7

تاریخ انتشار 2017-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023