Sensitive Voltammetric Detection of Indomethacin Using TiO2 Nanoparticle Modified Carbon Ionic Liquid Electrode

نویسندگان

چکیده مقاله:

In this work, a TiO2 nanoparticle modified carbon ionic liquid electrode (CILE) was employed as a sensitive sensor for the investigation of the electrochemical behavior of indomethacin (IND). This nanocomposite sensor has been fabricated by incorporation of TiO2 nanoparticles and the ionic liquid 1-hexylpyridinium hexafluorophosphate (HPFP). The surface of the electrode was studied by scanning electron microscopy (SEM). Differential pulse voltammetry (DPV) was used for quantification of sub-micromolar amounts of IND. Electrochemical parameters of the electrode reaction of IND, including the electron transfer coefficient (α) and the electron-transfer number (n), were calculated by cyclic voltammetry (CV) methods. Under selected conditions, the anodic peak current was linear for the concentration of IND in the broad range of 1.0 × 10-7 to 1.0 × 10-4 M with the detection limit of 2.1× 10-8 M. Moreover, the analytical performance of the proposed method for the determination of IND content in plasma samples was evaluated with good sensitivity and acceptable recoveries.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen

Monitoring the acetaminophen in biological samples and also in pharmaceutical formulations is important due to the concerns of public health care and drug safety. In this work a carbon paste electrode modified with BaTiO3 nanoparticle (BTO NPs) and room-temperature ionic liquid (IL) (n-hexyl-3-methylimidazolium hexafluoro phosphate) was fabricated. The direct electro-oxidation behavior of aceta...

متن کامل

Electrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode

In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...

متن کامل

Electrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode

In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...

متن کامل

Voltammetric Determination of Venlafaxine by Using Multiwalled Carbon Nanotube- Ionic Liquid Composite Electrode

The combination of multi-walled carbon nanotubes and ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP) yields a carbon nanocomposite (MWCNT-CILE) that can be well used aselectrode for electrocatalytic oxidation of venlafaxine (VEN). The influence of variousexperimental parameters including pH of the solution, the amount of multi-walled carbon nanotubeused for the modification of the car...

متن کامل

A Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay

We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...

متن کامل

Simultaneous Determination of Thiocyanate and Oxalate in Urine using a Carbon Ionic Liquid Electrode Modified with TiO2-Fe Nanoparticles

A carbon ionic liquid electrode (CILE) modified with TiO2-Fe nanoparticles was constructed by incorporating TiO2-Fe nanoparticles into the paste matrix. Under the optimized experimental conditions, using differential pulse voltammetry (DPV), the oxidation of thiocyanate and oxalate were occurred at potentials of 0.740 V and 1.010 V, respectively, at the surface of the modi...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 7  شماره 1

صفحات  89- 98

تاریخ انتشار 2020-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023