The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner

نویسندگان

  • H. Arabi
  • S.M. Aghamiri
چکیده مقاله:

Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoretical study of the effect of X-ray focal spot on the spatial resolution of VRX CT is presented in this paper. In this study, we used the parameters of an actual VRX CT scanner. By using the relevant equations, the effects of foal spot sizes of 0.6 and 0.1 mm were calculated on spatial resolution of the system at various opening half angles. Results: Focal spot size of 0.6 mm had no significant effect on spatial resolution of the system for opening half angles of above 14°. Even focal spot sizes of larger than 0.6 mm could not affect the spatial resolution of the system. For opening half angles of below 14°, foal spot size of 0.6 mm limited the spatial resolution of the system to 5.7 cycle/mm and caused great spatial resolution non-uniformity along the detector length. Conclusion: By focal spot size of 0.1 mm, the spatial resolution varied as a function of the opening half angle and increased to more than 30 cycle/mm. Additionally, focal spot size of 0.1 mm minimized the spatial resolution non-uniformity along the detector length. Iran. J. Radiat. Res., 2010 8 (1): 37-43

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the effect of focal spot size on the spatial resolution of variable resolution x-ray ct scanner

background: a variable resolution x-ray (vrx) ct scanner provides a great increase in the spatial resolution. in vrx ct scanners, the spatial resolution of the system and its field of view (fov) can be changed according to the object size. one of the main factors that limit the spatial resolution of vrx ct scanner is the effect of the x-ray focal spot. materials and methods: a theoretical study...

متن کامل

Investigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT

Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...

متن کامل

the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)

cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...

the washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests

در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره None

صفحات  37- 43

تاریخ انتشار 2010-06

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023