Validation of an Analytical Method for Determination of Benzo[a]pyrene Bread using QuEChERS Method by GC-MS

نویسندگان

  • Farzad Kobarfard Department of Medicinal Chemistry, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran, Phytochemistry Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Katayoun Javidnia Medicinal and Natural Products Chemistry Research Centre, Shiraz University of Medical Sciences, Shiraz, Iran
  • Mitra Bayat Phytochemistry Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Najmeh Khalighian Medicinal and Natural Products Chemistry Research Centre, Shiraz University of Medical Sciences, Shiraz, Iran
  • Ramezan Sadeghi Department of Pharmacology and Toxicology, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Samira Eslamizad Department of Pharmacology and Toxicology, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Sara Shahanipour Medicinal and Natural Products Chemistry Research Centre, Shiraz University of Medical Sciences, Shiraz, Iran
چکیده مقاله:

A fast and simple modified QuEChERS (quick, easy, cheap, rugged and safe) extraction method based on spiked calibration curves and direct sample introduction was developed for determination of benzo[a]pyrene (BaP) in bread by gas chromatography-mass spectrometry single quadrupole selected ion monitoring (GC/MS-SQ-SIM). Sample preparation includes extraction of BaP into acetone followed by cleanup with dispersive solid phase extraction. The use of spiked samples for constructing the calibration curve substantially reduced adverse matrix-related effects. The average recovery of Bap at 6 concentration levels was in range of 95–120%. The method was proved to be reproducible with relative standard deviation less than 14.5% for all of the concentration levels. The limit of detection and limit of quantification were 0.3 ng/g and 0.5 ng/g, respectively. Correlation coefficient of 0.997 was obtained for spiked calibration standard over the concentration range of 0.5-20 ng/g. To the best of our knowledge, this is the first time that a QuEChERS method is used for analysis of BaP in breads. The developed method was applied for determination of Bap in 29 traditional (Sangak) and industrial (Senan) bread samples collected from Tehran in 2014. These results showed that two Sangak samples were contaminated with BaP. Therefore, a comprehensive survey for monitoring of BaP in Sangak bread samples seems to be needed. This is the first report concerning contamination of bread samples with BaP in Iran.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

validation of an analytical method for determination of benzo[a]pyrene bread using quechers method by gc-ms

a fast and simple modified quechers (quick, easy, cheap, rugged and safe) extraction method based on spiked calibration curves and direct sample introduction was developed for determination of benzo[a]pyrene (bap) in bread by gas chromatography-mass spectrometry single quadrupole selected ion monitoring (gc/ms-sq-sim). sample preparation includes extraction of bap into acetone followed by clean...

متن کامل

Validation of an Analytical Method for Simultaneous Determination of 18 Persistent Organic Pollutants in Trout Using LLE Extraction and GC-MS/MS

Persistent organic pollutants, (POPs), are vast distributed compounds in environment which are recognized as one of the global pollution problems. These groups of materials being dangerous due to their high stability are accumulated in animal tissues and occurring in the food chain. One of the major paths through which persistent organic combinations access to human body is consuming polluted f...

متن کامل

Validation of an Analytical Method for Simultaneous Determination of 18 Persistent Organic Pollutants in Trout Using LLE Extraction and GC-MS/MS

Persistent organic pollutants, (POPs), are vast distributed compounds in environment which are recognized as one of the global pollution problems. These groups of materials being dangerous due to their high stability are accumulated in animal tissues and occurring in the food chain. One of the major paths through which persistent organic combinations access to human body is consuming polluted f...

متن کامل

Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS

Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره 2

صفحات  465- 474

تاریخ انتشار 2016-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023