نتایج جستجو برای: 3d dosimetry

تعداد نتایج: 196009  

2016
Tze Yee Lim Rajat J. Kudchadker Jihong Wang Tharakeswara Bathala Janio Szklaruk Thomas J. Pugh Usama Mahmood Geoffrey S. Ibbott Steven J. Frank

PURPOSE Computed tomography (CT)-based prostate post-implant dosimetry allows for definitive seed localization but is associated with high interobserver variation in prostate contouring. Currently, magnetic resonance imaging (MRI)-based post-implant dosimetry allows for accurate anatomical delineation but is limited due to inconsistent seed localization. Encapsulated contrast agent markers were...

Journal: :Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms 2001
M Moscovitch G W Phillips

Three-dimensional optical random access memories (3D ORAMs) are a new generation of high-density data storage devices. Binary information is stored and retrieved via a light induced reversible transformation of an ensemble of bistable photochromic molecules embedded in a polymer matrix. This paper describes the application of 3D ORAM materials to radiation dosimetry. It is shown both theoretica...

Journal: :Physics in medicine and biology 2016
S Dahdouh N Varsier M A Nunez Ochoa J Wiart A Peyman I Bloch

Numerical dosimetry studies require the development of accurate numerical 3D models of the human body. This paper proposes a novel method for building 3D heterogeneous young children models combining results obtained from a semi-automatic multi-organ segmentation algorithm and an anatomy deformation method. The data consist of 3D magnetic resonance images, which are first segmented to obtain a ...

2009
A. Berg

Modern radiation techniques aim on improved 3-dimensional (3D) spatial selectivity of the dose application sparing dose from organs-at-risk (e.g. IMRT with micro-multileaf collimation, γ-knife-, Brachyand heavy-ion therapy). The corresponding 3D-dose distributions exhibit high dose gradients above 4 Gy/mm, which are difficult to be investigated using standard single-point dosimetric detectors ...

2016
Ryosuke Kohno Hidenori Yamaguchi Kana Motegi Kenji Hotta Shie Nishioka Tetsuo Akimoto

The radiation positioning system (RADPOS) combines an electromagnetic positioning sensor with metal oxide semiconductor field-effect transistor (MOSFET) dosimetry, enabling simultaneous online measurement of dose and spatial position. Evaluation points can be determined with the RADPOS. The accuracy of in-vivo proton dosimetry was evaluated using the RADPOS and an anthropomorphic head and neck ...

Journal: :iranian journal of radiation research 0
h. nan department of biomedical engineering, school of bioengineering, chongqing university, chongqing 400030, china s. jinlu department of radiation oncology, chongqing daping hospital, chongqing, 400042, china z. shaoxiang department of anatomy, institution of digital medicine, tmmu, chongqing 400038, china h. qing institute of nuclear science and technology, sichuan university, chengdu 610064, china t. li-wen department of anatomy, institution of digital medicine, tmmu, chongqing 400038, china g. chengjun institute of nuclear science and technology, sichuan university, chengdu 610064, china

background: accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. however, most of the existing voxel phantoms are constructed on the basis of caucasian or non-chinese population. materials and methods: a computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed based on chin...

2000
Konrad W. Leszczynski Peter B. Dunscombe

The checking of monitor unit calculations is recognized as a vital component of quality assurance in radiotherapy. Using straightforward but detailed computer-based verification calculations it is possible to achieve a precision of 1% when compared with a three-dimensional (3D) treatment planning system monitor unit calculation. The method is sufficiently sensitive to identify significant error...

Journal: :Applied sciences 2021

The aim of this study was to develop and apply an evaluation method for assessing the accuracy a novel 3D EPID back-projection algorithm in vivo dosimetry. Dosimetry Check (DC) 5.8 evaluated. A slab phantom homogeneously filled, or with air bone inserts, used fluence reconstruction different squared fields. VMAT plans anatomical sites were delivered on anthropomorphic phantom. Dose distribution...

2016
Laurence Autret Julien Bert Yannick Lemaréchal Laurent Desbat Dimitris Visvikis

The verification of the dose delivered to a patient during radiation therapy is a particularly important step for ensuring treatment quality. This step, known as in vivo dosimetry can be realized using a bidimensional dosimeter named Electronic Portal Imaging Device (EPID). However, few methods enable the determination of an accurate and fully personalized 3D dose distribution for the most curr...

Journal: :Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention 2009
Jérémie Anquez Tamy Boubekeur Lazar Bibin Elsa D. Angelini Isabelle Bloch

Potential sanitary effects related to electromagnetic fields exposure raise public concerns, especially for fetuses during pregnancy. Human fetus exposure can only be assessed through simulated dosimetry studies, performed on anthropomorphic models of pregnant women. In this paper, we propose a new methodology to generate a set of detailed utero-fetal unit (UFU) 3D models during the first and t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید