In this paper, the ratio of adsorbed dose to the tissues of muscle, blood and bone to water for medical accelerators of Electa 25MV and Siemens 6MV is calculated using an analytical method based on cavity theory and Monte Carlo simulation. To confirm the validation of these methods, the ratio of absorbed dose to air to water was determined experimentally for radiation field of 60Co in Secondary...
Introduction Radiotherapy is regarded as the first treatment of choice for nasopharyngeal carcinoma. Despite the advantages of radiotherapy, patients may suffer from a wide range of side-effects due to the presence of many sensitive normal tissues in these regions. If the absorbed dose exceeds the tolerance level in parotid glands and the spinal cord, myelopathy, Lhermitte's sign and xerostomia...
Within our activities on accelerator-based boron neutron capture therapy (BNCT) carried out at the Tandar Laboratory (Comisión Nacional de Energı́a Atómica, Argentina) we present here the study and design of a tomographic imaging system for the measurement of the spatial distribution of the absorbed dose during a BNCT session. The 10B(n,α)7Li boron neutron capture reaction produces a 478 keV gam...
a 65 year old male with metastatic colorectal cancer (mcrc) in the liver was referred for selective internal radionuclide therapy (sirt) following a history of extensive systemic chemotherapy. 90y pet imaging was performed immediately after treatment and used to confirm lesion targeting and measure individual lesion absorbed doses. lesion dosimetry was highly predictive of eventual response in ...
The main detectors used for clinical dosimetry are ionisation chambers and semiconductors. Thermoluminescent (TL) dosimeters are also of interest because of their following advantages: i) wide useful dose range, ii) small physical size, iii) no need for high voltage or cables, i.e. stand alone character, and iv) tissue equivalence (LiF) for most radiation types. TL detectors can particularly be...
Background: Natural radionuclides in rock samples, primarily 238U (uranium), 232Th (thorium) and 40K (potassium), are the main source of radiation exposure to workers and general public and their measurement is of paramount importance from radiation protection point of view. Materials and Methods: Gamma spectrometry using HPGe detector was used to measure the radioactivity and assess the radiol...
The purpose of this study was to ensure accuracy in radiation dose delivery, external dosimetry quality audit has an equal importance with routine dosimetry performed at clinics. To do so, dosimetry quality audit was organized by the Secondary Standard Dosimetry Laboratory (SSDL) of Pakistan Institute of Nuclear Science and Technology (PINSTECH) at the national level to investigate and minimize...
BACKGROUND AND AIM: Due to increasing use of X-rays in diagnosis and treatment of diseases, this study aimed to measure and compares the absorbed dose in a number of sensitive organs of head and neck in different radiographic techniques.METHODS: Thermoluminescence dosimeter (TLD) and a male equivalent RANDO phantom were used to measure the absorbed dose in organs. The dosimeters were set in cer...