The use of continuous in-line blood gas management (CILBGM) is steeped in controversy concerning its potential utility and impact on patient outcomes. The purpose of this study was to determine whether the use of CILBGM results in improved quality of patient care. Fifty-nine patients were enrolled in a Institutional Review Board-approved, prospective, randomized study. An in-line blood gas moni...
CONTEXT Sudden cardiac death is one of the leading causes of death in Europe, and early prognostication remains challenging. There is a lack of valid parameters for the prediction of survival after cardiac arrest. AIMS This study aims to investigate if arterial blood gas parameters correlate with mortality of patients after out-of-hospital cardiac arrest. MATERIALS AND METHODS All patients ...
Advancement in oxygenator membrane technology has further expanded the boundaries in the clinical application of extracorporeal carbon dioxide removal (ECCO2R). Despite the advent of modern poly-4-methyl-1-pentene (PMP) membranes, limited information exists on the performance of these membranes at low sweep gas and blood flows. Moreover, physiological relationships for CO2 removal at these flow...
Arterial blood gas sampling is a very important investigation in the assessment of a patient’s acidbase status and oxygenation in acute and chronic bronchial asthma. It is the gold standard test which measures amounts of oxygen and carbon dioxide as well as the pH of the blood while it also evaluates the effective delivery of oxygen to the blood by the lungs and effective elimination of the car...
16 October 2007 ■ MLO www.mlo-online.com T he significance of good practice during the pre-testing phase of clinical-laboratory investigation cannot be overemphasized. The production of high-quality, accurate results, which are clinically useful, depends as much on practice before the patient’s sample reaches the laboratory as it does on the analytical phase within the laboratory. There are few...
The objective of this study was to measure differences between arterial and venous blood gas parameters and to evaluate whether arterial blood gas values can be estimated from venous blood in Asiatic black bears (ABBs). Twelve healthy captive ABBs (8 males and 4 females; 8-16 years; 76.8-220 kg) were included in this study. The bears were immobilized with medetomidine and zolazepam-tiletamine u...
Like humans, the heart rate (HR) of anesthetized rats immersed in CO(2)-water is lower than that when immersed in tap water at the same temperature. To investigate the afferent signal pathway in the mechanism of HR reduction, Wistar rats were anesthetized with urethane and then the spinal cord was transected between T(4) and T(5). The animals were immersed up to the axilla in a bathtub of tap-w...
Introduction In recent years, quality control has been extended to an everincreasing number of biochemical parameters. Its application to blood-gas analysis is complicated by two main factors: the need for reliable, reproducible quality control materials and the variability of calibration standards among the different clinical departments using blood gas apparatus ]. Moreover, automatic analyse...
The portable blood gas analyzer OPTI Critical Care Analyzer was evaluated in comparison to routine laboratory assays using heparinized blood samples of adults and newborns. Within-run imprecision studies were performed with native blood using tonometry to adjust blood gas concentrations. The results obtained show a very close agreement between the OPTI system and the comparison methods for all ...