نتایج جستجو برای: brachytherapy tg 43 formalism

تعداد نتایج: 156742  

2015
Christian N. Valdés Gustavo H. Píriz Enrrique Lozano

The aim of this work is to evaluate the performance of a commercial brachytherapy treatment planning system (TPS) with TG-43 Vendors Input Data (VID), analyze possible discrepancies with respect to a proper reference source and its implications for standard treatments, and judge the effectiveness of certain widespread recommended quality controls to find potential errors related with the interp...

2016
Michael S. Gossman

The process for validating dose-volume histogram data in brachytherapy software is presented as a supplement to a previously published article. Included is the DVH accuracy evaluation of the Best NOMOS treatment planning system called "Best TPS VolumePlan." As done previously in other software, a rectangular cuboid was contoured in the treatment planning system. A single radioactive 125I source...

M. Sadeghi, O. Kiavar,

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

Journal: :iranian journal of radiation research 0
o. kiavar department nuclear engineering, science and research branch, islamic azad university, tehran, iran m. sadeghi agricultural, medical & industrial research school, nuclear science and technology research institute, karaj, iran

background: recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. in this study a unique radioactive source for intra vascular brachytherapy (ivbt) was investigated. the two-dimensional dose distribution in water for a 32p ivbt stent has been calculated. the pure beta emitter source 32p has been coated on p...

2003
John J. DeMarco Timothy D. Solberg Nzhde Agazaryan

We describe a method for independently verifying the dose distributions from pre- and post-implant brachytherapy source distributions. Monte Carlo calculations have been performed to characterize the three-dimensional dose distribution in water phantom from a low-energy brachytherapy source. The calculations are performed in a voxelized, Cartesian coordinate geometry and normalized based upon a...

Journal: :Medical physics 2004
Firas Mourtada Christopher G Soares John L Horton

A new high dose rate 20 mm 32P intravascular brachytherapy (IVB) beta source used with automated stepping has recently been introduced. The AAPM Task Group 60 recommends that beta IVB sources should have well characterized dosimetric parameters in water. In this study, Monte Carlo simulations (MCNPX v 2.4) were used to derive these parameters for a 2 mm source segment rather than the entire 20 ...

2013
Evaggelos Pantelis Panagiotis Papagiannis Giorgos Anagnostopoulos Dimos Baltas

PURPOSE To determine the relative dose rate distribution around the new (125)I brachytherapy source IsoSeed I25.S17plus and report results in a form suitable for clinical use. Results for the new source are also compared to corresponding results for other commercially available (125)I sources of similar design. MATERIAL AND METHODS Monte Carlo simulations were performed using the MCNP5 v.1.6 ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید