نتایج جستجو برای: cu2 selective electrode
تعداد نتایج: 263337 فیلتر نتایج به سال:
In the present study, a new chemically modified carbon paste electrode (CPE) is constructed for rapid, accurate, simple, highly sensitive, and selective determination of Mo (VI) using differential pulse voltammetry. The electrode was prepared using magnetic nickel zinc ferrite nanocomposite (Ni0.5Zn0.5Fe2O4), as the modifier in CPE (Ni0.5Zn0.5Fe2O4/CPE). Mo (VI) was determined after preconcentr...
Potentiometric investigation on {H2O+NaNO3+PEG1500} mixtures were made at T=308.15K, using electrochemical cells with two ion-selective electrodes, (Na+ glass) as the cation ion-selective electrode against (NO3- solvent-polymer PVC) as the anion ion-selective electrode. The mean ionic activity coefficients of NaNO3 were measu...
Two Cu2+-specific colorimetric sensors, based on ferrocene-carbohydrate bioconjugates, 2, C46H56O20N6Fe and 3, C28H33O10N3Fe were designed and synthesized in good yields. Both the compounds, 2 and 3, behave as very selective and sensitive chromogenic and electrochemical chemosensor for Cu2+ ion in aqueous environment (CH3CN/H2O (2:8, v/v). The analytical detection limit (ADL) for receptor 2 was...
a new poly(vinylchloride) membrane sensor for cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. the electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with anernstian slope of 20.3 ± 0.5 mv per decade and a detection limit of 2×10-7. it has a fast responsetime of
A new Cu2+ compound Cu- NB, (where H2 NB is bis(2-hydroxyl-naphthalene-carboxaldehyde) benzil dihydrazone) was synthesized as a highly selective fluorescence chemosensor for the detection of Hg2+ in aqueous media through a displacement "turn-on" signaling strategy. Whereas the coordination of Cu2+ resulted in a considerable quenching of the typical luminescence of the naphthol rings in Cu-NB, t...
The behaviors of 15 kinds of metal ions in the thiol-capped CdTe quantum dots (QDs)-H2O2 chemiluminescence (CL) reaction were investigated in detail. The results showed that Ag+, Cu2+ and Hg2+ could inhibit CdTe QDs and H2O2 CL reaction. A novel CL method for the selective determination of Ag+, Cu2+ and Hg2+ was developed, based on their inhibition of the reaction of CdTe QDs and H2O2. Under th...
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید