نتایج جستجو برای: current injection

تعداد نتایج: 923565  

2001
Jun'ichi Sone Toshishige Yamada

A new current-injection Josephson latch employing a single-flux quantum is proposed. It has a master-slave circuit configuration and operates under ac power supply. In the circuit, data are stored as a circulating current in a superconducting loop consisting of a single junction and inductances. A two-junction interferometer gate directly coupled to the l.oop reads out the stored data. Dual-rai...

2009
Pantana Tor-ngern

ii 1 Overview 1.1 Motivation ............................................................................1 1.2 The Challenge ........................................................................2 2 Background 2.1 Two-dimensional Photonic Crystal ................................................3 2.2 Two-dimensional Photonic Crystal Laser Cavity ................................6 3 Design and A...

2005
Nelson Tansu Luke J. Mawst

The concept of below-threshold and above-threshold current injection efficiency of quantum well sQWd lasers is clarified. The analysis presented here is applied to the current injection efficiency of 1200 nm emitting InGaAs and 1300 nm emitting InGaAsN QW lasers. The role of heavy-hole leakage in the InGaAsN QW lasers is shown to be significant in determining the device temperature sensitivity....

2009
Brian A. Ruzicka Hui Zhao

We investigate the power dependence of pure spin current injection in GaAs bulk and quantum-well samples by a quantum interference and control technique. Spin separation is measured as a function of the relative strength of the two transition pathways driven by two laser pulses. By keeping the relaxation time of the current unchanged, we are able to relate the spin separation to the injected av...

2012
André Revil

S U M M A R Y Acoustic wavefields produced using sources appropriately delayed in time can be focused at known positions and times in a heterogeneous medium. Seismoelectric conversion occurs if the acoustic focus point coincides with a discontinuity in electrical and hydrological medium properties, thus generating a current density. The current generates a potential difference, which can be obs...

2001
MICHAEL J. COUSINS Robert Cluff Steven P. Cohen Yuchiao Chang Christine N. Sang Milan P. Stojanovic

Although epidural steroid injections (ESIs) are a common treatment for chronic pain conditions, it is not clear whether there is consensus on their technical aspects. The current literature suggests that variations in technical aspects may affect ESI outcomes. The goal of the survey was to help establish a standard frame of reference for the performance of ESIs. We analyzed survey results from ...

Journal: :Journal of neurophysiology 2016
Hilary E Wakefield Ralph F Fregosi Andrew J Fuglevand

The maximum firing rates of motoneurons (MNs), activated in response to synaptic drive, appear to be much lower than that elicited by current injection. It could be that the decrease in input resistance associated with increased synaptic activity (but not current injection) might blunt overall changes in membrane depolarization and thereby limit spike-frequency output. To test this idea, we rec...

2017
F. Fang Y. W. Yin Qi Li G. Lüpke

Electrical manipulation of magnetism presents a promising way towards using the spin degree of freedom in very fast, low-power electronic devices. Though there has been tremendous progress in electrical control of magnetic properties using ferromagnetic (FM) nanostructures, an opportunity of manipulating antiferromagnetic (AFM) states should offer another route for creating a broad range of new...

2014
V. G. Kogan R. G. Mints

New thin-film Josephson junctions have recently been tested in which the current injected into one of the junction banks governs Josephson phenomena. One thus can continuously manage the phase distribution at the junction by changing the injected current. A method of calculating the distribution of injected currents is proposed for a half-infinite thin-film strip with source-sink points at arbi...

2016
Shigang Wang Ren Ma Shunqi Zhang Tao Yin Zhipeng Liu

BACKGROUND Magneto-acoustic tomography with current injection involves using electrical impedance imaging technology. To explore the potential applications in imaging biological tissue and enhance image quality, a new scan mode for the transducer is proposed that is based on translational and circular scanning to record acoustic signals from sources. METHODS An imaging algorithm to analyze th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید