This paper proposes a wireless ZigBee technology to monitor the parameters of the transformer. The transformer parameters such as voltage, current, power factor and temperature can be monitored through wireless ZigBee technology. Embedded Ethernet is used to develop client and server applications. Acquisition of voltages, currents, temperatures, active and reactive power, controlling the switch...
harmonics have become an important issue in modern power systems. the widespread penetration of non-linear loads to emerging power systems has turned power quality analysis into an important operation issue under both steady state and transient conditions. this paper employs an extended harmonic domain (ehd) based framework for dynamic analysis of long term analysis over voltages during the tra...
Original scientific paper Measurement of grid voltage harmonic components is an important part of power quality measurements. Current high voltage transformers with iron core are not linear and cannot easily be used for accurate measurement of "polluted" voltages in wide frequency range. In this paper, design details of a new coreless voltage transformer for power quality measurement are given....
More and more sub-stations are retrofitted with numerical relays, meters and monitoring devices. Most often, the older relay gets replaced with a newer relay with the rest of the installation such as Current Transformer (CT) and lead remaining undisturbed. Utilities have standardized on their older current transformers and want to maintain the same current transformer specifications throughout ...
During the transient period at the start of transformer energization, it experiences a flux linkage that is up to twice its nominal steady state value and saturates the core. This causes a large inrush current to flow which affects the power system stability and power quality especially when the source is weak. Sequential phase energization technique and addition of neutral resistor are the maj...
A new primary-side-assisted zero-voltage and zerocurrent switching full bridge dc–dc converter with transformer isolation is proposed. The proposed dc–dc converter uses only one auxiliary transformer and two diodes to obtain ZCS for the leading leg. It has a simple and robust structure, and load current control capability even in short circuit conditions. Possibility of magnetic saturation due ...
This paper deals with diagnostic methods of the internal faults in power transformers. The diagnostic process uses some of the current diagnosis methods (e.g. oil test, dissolved gases analysis (DGA), partial discharge (PD), etc.) to determine the condition of the transformer. In this process, the most frequent diagnostic methods were listed and applied practically to be compared. A conventiona...
Among the most noticeable root causes of improper performance in power transformers, internal short circuit faults can be noted and if not quickly be identified and addressed in the accepted time interval, irrecoverable damages such as interruption or even collapse of the network connected to the power transformer would happen. In this contribution, three-phase transformer behaviors under magne...
(Received: October 30, 2011; Accepted: December 8, 2011) Abstract: This paper presents a novel technique for transformer differential protection to prevent incorrect operation due to inrush current. The proposed method in this paper is based on time-frequency transform known as the Wavelet transform. The discrete Wavelet transform is used for analysis the differential current signals in time an...