نتایج جستجو برای: disinfection process
تعداد نتایج: 1319631 فیلتر نتایج به سال:
BACKGROUND: The current standards for chlorine and monochloramine disinfection of drinking water were established using information obtained from bench-scale disinfection experiments of monodispersed hepatitis A virus. It is not clear whether these standards are sufficient for the four virus types listed on the CCL2. Several disinfection studies have been conducted on representative coxsackievi...
Ultraviolet light (UV) is a recognized disinfection alternative to chlorine and ozone in many applications from drinking water to wastewater treatment. UV provides effective disinfection without production of problematic disinfection byproducts. Information on the mechanism and application of UV for drinking water disinfection is presented. Advantages and disadvantages of the technique are disc...
Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor.
Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly ...
The objective of this manuscript was to assess the toxicity formation on biological treated wastewater from a municipal wastewater treatment plant, after a chlorination-dechlorination disinfection process. Water was monitored by means of physicochemical and ecotoxicological parameters, with the use of Vibrio fischeri bioassay. Since a dechlorination process removed residual chlorine, the positi...
This study evaluated the effect of disinfection methods [chemical disinfection (immersion in 100 ppm chloride solution) or microwave disinfection (690 W for 6 min)] on the internal adaptation of denture bases and resin surface roughness. For the adaptation test, 18 maxillary denture bases were obtained from stone casts duplicated from a metallic master model and submitted to the following treat...
BACKGROUND Stethoscopes are contaminated with bacteria, but predictors of stethoscope disinfection frequency are unknown. We sought to describe health care provider stethoscope disinfection attitudes and practices and determine predictors of frequent disinfection. METHODS We used an anonymous online survey of nurses, nurse practitioners, and physicians at a pediatric hospital. We assessed fre...
Giardia duodenalis is a protozoan of public health interest that causes gastroenteritis in humans and other animals. In the city of Campinas in southeast Brazil, giardiasis is endemic, and this pathogen is detected at high concentrations in wastewater effluents, which are potential reservoirs for transmission. The Samambaia wastewater treatment plant (WWTP) in the city of Campinas employs an ac...
BACKGROUND There are great interests in photocatalytic oxidation of contaminants using titanium dioxide in recent years. The main objective of this research was to study photocatalytic disinfection of Coliform bacteria as water microbial pollution index using TiO2 and a low pressure UV lamp in a batch reactor. METHODS The polluted water was prepared by adding a colony of Coliform in raw water...
Many drinking water utilities have recently changed or are seriously considering changing their disinfection practice from chlorine to some alternative treatment process. However, most of these utilities are changing their disinfectants without evaluating chemical impacts. Therefore, a research cooperative agreement was developed with Jefferson Parish, LA, to evaluate four parallel streams trea...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید