نتایج جستجو برای: dose calculation accuracy
تعداد نتایج: 730852 فیلتر نتایج به سال:
Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...
Unlike scheduled radiotherapy treatments, treatment planning time and resources are limited for emergency treatments. Consequently, plans are often simple 2D image-based treatments that lag behind technical capabilities available for nonurgent radiotherapy. We have developed a novel integrated urgent workflow that uses onboard MV CBCT imaging for patient simulation to improve planning accuracy ...
Log file-based methods are attracting increasing interest owing to their ability to validate volumetric-modulated arc therapy outputs with high resolution in the leaf and gantry positions and in delivered dose. Cross-validation of these methods for comparison with measurement-based methods using the ionization chamber/ArcCHECK-3DVH software (version 3.2.0) under the same conditions of treatment...
PURPOSE The purpose of this study is to improve dose calculation accuracy of the simplified Monte Carlo (SMC) algorithm in the low-dose region. Because conventional SMC algorithms calculate particle scattering in consideration of multiple Coulomb scattering (MCS) only, they approximate lateral dose profiles by a single Gaussian function. However, it is well known that the low-dose region spread...
Metal implants which saturate the CT number scale may require dosimetrist and physicist involvement to manually contour and assign an appropriate value to the metal for accurate dose calculation. This study investigated dose calculation based directly on extended CT scale images for different metals and geometries. The aim was to evaluate extended CT accuracy as a suitable alternative to standa...
Introduction: Heterogeneity correction is an important parameter in dose calculation for cancer patients where it may be cause inaccuracy in dose calculation as a result of different densities of patients. This study studied the impact of dose calculation of breast cancer patients with and without heterogeneity correction. Material and Methods: Twenty breast cancer patients were treated with Th...
PURPOSE To verify the clinical pencil beam dose calculation algorithm for passive scattering proton therapy using field with large range in tissue, i.e. in prostate cancer, using a Monte Carlo (MC) simulation system. METHODS Previously treated prostate cancer cases were randomly selected from our patient database. All patients received the same dose prescription of 50Gy (25 fractions) to plan...
background: in radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. in this study, the two available calculation algorithms of the varian eclipse 8.6 treatment planning system(tps), the anisotropic analytic algorithm (aaa) and pencil-beam convolution (pbc) was used to compare measured and calculated peripheral dose distributi...
PURPOSE To investigate effects of metal artifacts on the dose calculation accuracy of three dose calculation algorithms on CT and cone-beam CT images. METHODS A phantom with and without metal objects was scanned using CT simulator and on-board kV CBCT. Conformal 5-field treatment plans with identical physical and dosimetric parameters were created in the Eclipse™ treatment planning system for...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید