نتایج جستجو برای: dose calculation inhomogeneity phantom tigrt

تعداد نتایج: 427787  

M. Allahverdi, M.H. Zahmatkesh, M.R. Ay, N. Riyahi Alam, T. Allahverdi Pourfallah,

Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of...

2017
M. Keshtkar A. Takavar M. H. Zahmatkesh H. A. Nedaie A. Vaezzadeh M. Naderi

Background: Some ssues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calcula on in order to achieve an accurate dose delivery. Dose verifica on in complex radia on therapy techniques, such as intensity‐modulated radia on therapy (IMRT) calls for volumetric, ssue equivalent and energy independent dosimeter. The purpose of this study i...

Journal: :Medical physics 2005
Jan Seuntjens Marina Olivares Michael Evans Ervin Podgorsak

For reasons of phantom material reproducibility, the absorbed dose protocols of the American Association of Physicists in Medicine (AAPM) (TG-51) and the International Atomic Energy Agency (IAEA) (TRS-398) have made the use of liquid water as a phantom material for reference dosimetry mandatory. In this work we provide a formal framework for the measurement of absorbed dose to water using ioniz...

A. Jabbary Arfaee, A.S. Meigooni, E. Rajab Bolookat, H.A. Nedaie, H.R. Mirzaei, R. Jaberi, S. Gholami, S. Rabi Mahdavi,

Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...

2005
Wendel Dean Renner Kevin Norton Timothy Holmes

A method to convert integrated electronic portal imaging device (EPID) images to fluence for the purpose of reconstructing the dose to a phantom is investigated here for simple open fields. Ultimately, the goal is to develop a method to reconstruct the dose to patients. The EPID images are transformed into incident intensity fluence by spatial filtering with a deconvolution kernel. The kernel u...

Journal: :basic and clinical cancer research 0
hoda darestani 1nuclear engineering department, science and research unit, azad university, tehran, i.r. iran hassan ali nedaie radiotherapy oncology department, cancer institute, tehran university of medical sciences, tehran, i.r. iran azim arbabi radiation oncology department, imam hussein medical center, faculty of medicine, shahid beheshti university of medical sciences, tehran, i.r. iran kheirollah mohammadi nuclear engineering department, amirkabir industrial university, tehran, i.r. iran mahmood allahverdi radiotherapy oncology department, cancer institute, tehran university of medical sciences, tehran, i.r. iran arjang shahvar agricultural, medical and industrial research school, karaj, i.r. iran

background : in spite of clinically useful photon and electron beams, high energy linacs produce secondary particles such as neutrons (photo-neutron production). neutrons have important roles during treatment with high energy photons in terms of protection and dose escalation. in this project, neutron dose equivalent of 18 mv varian accelerators is calculated by tld600 and tld700. materials and...

2017
Chenyu Yan Anthony G Combine Greg Bednarz Ronald J Lalonde Bin Hu Kathy Dickens Raymond Wynn Daniel C Pavord M Saiful Huq

PURPOSE The main aim of this study is to validate the Acuros XB dose calculation algorithm for a Varian Clinac iX linac in our clinics, and subsequently compare it with the wildely used AAA algorithm. METHODS AND MATERIALS The source models for both Acuros XB and AAA were configured by importing the same measured beam data into Eclipse treatment planning system. Both algorithms were validated...

2012
A. Sahebnasagh

Relation to high absorption fraction of Tc sestamibi by kidneys in heart scan and these organs are near to generation organs (Ovaries and uterus). Urinary system (kidneys and urinary bladder) are specified as sources organs. The main object of this study is to determine the absorbed dose in these critical organs. we have set amount of absorbed fraction radiopharmaceutical in position of kidneys...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید