نتایج جستجو برای: dose profile
تعداد نتایج: 520949 فیلتر نتایج به سال:
background: changes in body composition may be used for monitoring progression/ regression of a disease. prompt γ-rays in vivo neutron activation analysis (ivnaa) has been widely used for the measurement of body composition in recent years. objective: in this paper, we tried to improve the safety of ivnaa operator. methods: the most important factor for reducing the operator receiving dose is t...
introduction: nowadays, considerable developments in the field of radiotherapy have been achieved. they include the advances made in the equipments and treatment planning techniques which require highly complex calculations. such achievements have made it possible to treat cancer patients not only with higher radiation dose but also with higher precision and con...
BACKGROUND Preclinical studies have demonstrated that MIS416, a bacterially derived immune modulator, targets myeloid cells following systemic delivery. MIS416 stimulated myeloid cells have the capacity to regulate innate inflammation, a potential therapeutic target for progressive multiple sclerosis. OBJECTIVES To determine the safety, tolerability, pharmacodynamics and maximum tolerated dos...
The stability of delivery of low monitor unit (MU) setting is important especially for step-andshoot intensity-modulated radiotherapy (IMRT), because the nature of the technique is inherent to repeat beam on/off according to the number of the segments. This study evaluates the dose linearity and profile flatness/symmetry under low MU settings for Vero4DRT, a new linear-accelerator based irradia...
The safety profile of HibMenCY was compared with licensed Hib conjugate vaccines in a pooled analysis that included more than 8,500 subjects who were administered a four-dose series of HibMenCY or commercially available Hib vaccines at 2, 4, 6 and 12-15 mo of age in two primary vaccination and two fourth dose phase 3 studies. In all studies, HibMenCY or Hib vaccine was co-administered with age-...
Purpose: This paper evaluates the mechanical parameters for three dimensions PTW automatic water phantom system (MP3-S) and its computer controlled measuring system (MEPHYSTO software version 7.3). Material and Methods: This study compares the scanning overall speed using the PTW water phantom and PTW MEPHYSTO software at different levels of overall speed 5, 10, 15, 20,30, 40, and 50mm/sec. The...
Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید