نتایج جستجو برای: dosimetry calculation

تعداد نتایج: 109521  

G. Chengjun, H. Nan, H. Qing, S. Jinlu, S.B. Jiang, T. Li-wen, X. Tang, Z. Shaoxiang, Z. Xiao-lin,

Background: Accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. Materials and Methods: A computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed base...

Journal: :Medical physics 1998
C G Soares D G Halpern C K Wang

The calibration of a catheter-based system to be used for therapeutic radiation treatment to prevent restenosis following interventional coronary procedures is described. The primary dosimetry was performed ionometrically using an extrapolation chamber equipped with a 1-mm diameter collecting electrode to measure absorbed dose in tissue equivalent plastic at a depth of 2 mm. These results are c...

Journal: :Medical physics 2013
Yuichi Akino Indra J Das Gregory K Bartlett Hualin Zhang Elizabeth Thompson Jennifer E Zook

PURPOSE Dosimetric accuracy in radiation treatment of breast cancer is critical for the evaluation of cosmetic outcomes and survival. It is often considered that treatment planning systems (TPS) may not be able to provide accurate dosimetry in the buildup region. This was investigated in various treatment techniques such as tangential wedges, field-in-field (FF), electronic compensator (eComp),...

2015
Wietske Woliner-van der Weg Rafke Schoffelen Robert F Hobbs Martin Gotthardt David M Goldenberg Robert M Sharkey Cornelis H Slump Winette TA van der Graaf Wim JG Oyen Otto C Boerman George Sgouros Eric P Visser

BACKGROUND Red bone marrow (RBM) toxicity is dose-limiting in (pretargeted) radioimmunotherapy (RIT). Previous blood-based and two-dimensional (2D) image-based methods have failed to show a clear dose-response relationship. We developed a three-dimensional (3D) image-based RBM dosimetry approach using the Monte Carlo-based 3D radiobiological dosimetry (3D-RD) software and determined its additio...

2000
Konrad W. Leszczynski Peter B. Dunscombe

The checking of monitor unit calculations is recognized as a vital component of quality assurance in radiotherapy. Using straightforward but detailed computer-based verification calculations it is possible to achieve a precision of 1% when compared with a three-dimensional (3D) treatment planning system monitor unit calculation. The method is sufficiently sensitive to identify significant error...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2001
M J Rivard

It is of interest to discern the energy-dependence of American Association of Physicists in Medicine (AAPM) TG-43 brachytherapy dosimetry parameters. Using Monte Carlo calculation geometry and techniques (MCNP), dependence of these parameters was calculated as a function of photon energy, in general, and for the MED3633 103Pd source using a discretized approach. Results were weighted and summed...

2006
Sarenée L. Cooper

A method for establishing electronic traceability, or e-traceability, of customer measurements to NIST high-dose measurement standards through the use of a measurement conversion factor (MCF) for Bruker e-scan instruments has been developed. The intent is that this factor will be incorporated into an Internet-based transfer dosimetry system, while still maintaining a reasonable and acceptable u...

Journal: :Radiation Measurements 2022

Organized by Working Group 6 “Computational Dosimetry” of the European Radiation Dosimetry (EURADOS), a group intercomparison exercises was conducted in which participants were asked to solve predefined problems computational dosimetry. The results these comparisons published series articles this virtual special issue Measurements. This paper reviews experience gained from various and highlight...

Journal: :Physica Medica 2021

PurposePatient-specific dosimetry in MRT relies on quantitative imaging, pharmacokinetic assessment and absorbed dose calculation. The DosiTest project was initiated to evaluate the uncertainties associated with each step of clinical workflow through a virtual multicentric trial. This work presents generation simulated SPECT datasets based GATE Monte Carlo modelling its corresponding experiment...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید