2000
Konrad W. Leszczynski Peter B. Dunscombe

The checking of monitor unit calculations is recognized as a vital component of quality assurance in radiotherapy. Using straightforward but detailed computer-based verification calculations it is possible to achieve a precision of 1% when compared with a three-dimensional (3D) treatment planning system monitor unit calculation. The method is sufficiently sensitive to identify significant error...

پایان نامه :وزارت علوم، تحقیقات و فناوری - موسسه آموزش عالی غیرانتفاعی و غیردولتی سجاد مشهد - دانشکده فنی 1393

location verification system

2016
Joanna Izewska Paulina Wesolowska Godfrey Azangwe David S. Followill David I. Thwaites Mehenna Arib Amalia Stefanic Claudio Viegas Luo Suming Daniela Ekendahl Wojciech Bulski Dietmar Georg

UNLABELLED The International Atomic Energy Agency (IAEA) has a long tradition of supporting development of methodologies for national networks providing quality audits in radiotherapy. A series of co-ordinated research projects (CRPs) has been conducted by the IAEA since 1995 assisting national external audit groups developing national audit programs. The CRP 'Development of Quality Audits for ...

2016
Laurence Autret Julien Bert Yannick Lemaréchal Laurent Desbat Dimitris Visvikis

The verification of the dose delivered to a patient during radiation therapy is a particularly important step for ensuring treatment quality. This step, known as in vivo dosimetry can be realized using a bidimensional dosimeter named Electronic Portal Imaging Device (EPID). However, few methods enable the determination of an accurate and fully personalized 3D dose distribution for the most curr...

Journal: :Medical physics 2006
Pengyi Guo John Adamovics Mark Oldham

There is a pressing need for a practical three-dimensional (3D) dosimetry system, convenient for clinical use, and with the accuracy and resolution to enable comprehensive verification of the complex dose distributions typical of modern radiation therapy. Here we introduce a dosimetry system that can achieve this challenge, consisting of a radiochromic dosimeter (PRESAGE) and a commercial optic...

Journal: :basic and clinical cancer research 0
alireza mohammadkarim department of engineering, science and research branch, islamic azad university, tehran, iran mahmoud allahverdi department of medical physics, tehran university of medical science, tehran, iran mahbod esfehani radiotherapeutic oncology department of cancer institute hasanali nedaie department of radiotherapy, tehran university of medical science, tehran, iran alireza shirazi department of medical physics, tehran university of medical science, tehran, iran

background: delivering the maximum dose to tumor while achieving the minimum dose delivery to normal tissue; is the most important goal in external radiotherapy. diode in vivo dosimetry is widely considered to be an important tool for quality improvement of patient care in external radiotherapy. uncertainty in dose delivery should fall within 5% of the prescribed dose as recommended by internat...

Journal: :iranian journal of medical physics 0
reza moghadam-drodkhani m.sc. in medical physics, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran nader riyahi-alam professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran abbas takavar professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran kavous firoznia associate professor, radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran peiman hadad associate professor, radiotherapy dept., imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran behrooz rafiee m.sc., radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran

introduction: the conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. although the polymer gel dosimetry method based on magnetic resonance imaging (mri) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...