This work describes a novel method for statistical analysis of multi-material components. The application scenario is industrial 3D X-ray computed tomography, emphasizing metrology of artefact affected plastics-metal components. The presented work makes use of dual energy CT data acquisition for artefact reduction, in order to optimize CT scans of multi-material components. Using statistical an...
For decades, dual-energy imaging has been used for tissue differentiation with several x-ray–based imaging modalities, exploiting the fact that the tissues in the human body show different absorption characteristics when penetrated with different x-ray spectra, spectra that are typically generated by different kV settings of the x-ray tube. Recently, dual-source computed tomography (CT) with 2 ...
OBJECTIVE Our aim was to determine, using CT attenuation values, the chemical composition of 241 human renal stones placed in a jelly phantom and to analyze the influence of respiratory motion on the classification. MATERIALS AND METHODS The stones were placed in a jelly simulating the X-ray attenuation of the kidneys. A dynamic platform was used to apply to the phantom free-breathing motion ...
CT is the preferred imaging modality to diagnose pulmonary embolism Evaluation of pulmonary embolism with dual energy CT (DECT) retains diagnostic accuracy using less contrast material than standard CT Virtual monochromatic images, derived from DECT data, show contrast material at greater intensity than standard CT Iodine images show the distribution of contrast material and can be used to asse...
S71 ______________________________________________________________________________________________________ provided by dual-energy CT (DECT) compared to singleenergy CT (SECT) can be clinically used to reduce CT-based range uncertainties and to analyze intraand interpatient tissue variations. First, a DECT scan protocol was optimized and clinically introduced. Second, in a first analysis patien...
The introduction of a dual-source CT system in the same gantry resolved many of the technical issues that previously limited the application of dual-energy CT pulmonary angiography. Dual-energy CT pulmonary angiography does not expose patients to any significant additional radiation beyond that of standard CT pulmonary angiography [1, 2]. Post-processing software is then used to subtract 80-kV ...
We read with interest the article by Gafton et al published in 2012. The authors illustrated the use of a dual-phase CT protocol for the enhancement characterization of parathyroid lesions and suggested the elimination of precontrast and delayed scan phases from 4D CT to reduce radiation exposure. In this letter, we describe the alternative approach of our institution to 4D CT. Our modified 4D ...