نتایج جستجو برای: electronic portal imaging

تعداد نتایج: 704364  

Journal: :Medical physics 2009
Arun Gopal Sanjiv S Samant

Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal...

J. Zhou, L. Bai L. Bai, W. Zhang, X. Ke, Y. Wen, Y. Xie, Y. Zhang, Z. Zhang,

Background: To retrospectively evaluate whether quantitative information derived from spectral imaging can improve the differential diagnosis of pancreatic cystic masses including pancreatic solid pseudopapillary epithelial neoplasms (SPENs), mucin- producing cysts and pseudocysts. Materials and Methods: From June 2015 to October 2017, 56 patients (22 pseudocysts, 18 mucin-producing cysts and 1...

Journal: :Medical physics 2010
Sean L Berry Cynthia S Polvorosa Cheng-Shie Wuu

PURPOSE Portal dose images acquired with an amorphous silicon electronic portal imaging device (EPID) suffer from artifacts related to backscattered radiation. The backscatter signal varies as a function of field size (FS) and location on the EPID. Most current portal dosimetry algorithms fail to account for the FS dependence. The ramifications of this omission are investigated and solutions fo...

2014
Pejman Rowshanfarzad Conor K McGarry Michael P Barnes Mahsheed Sabet Martin A Ebert

BACKGROUND In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of en...

Journal: :Medical physics 2006
Markus Wendling Robert J W Louwe Leah N McDermott Jan-Jakob Sonke Marcel van Herk Ben J Mijnheer

The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous silicon EPID. By using this back-projection algorithm, two-dimensional dose distr...

Journal: :Medical physics 2004
L N McDermott R J W Louwe J J Sonke M B van Herk B J Mijnheer

The purpose of this study was to investigate the dose-response characteristics, including ghosting effects, of an amorphous silicon-based electronic portal imaging device (a-Si EPID) under clinical conditions. EPID measurements were performed using one prototype and two commercial a-Si detectors on two linear accelerators: one with 4 and 6 MV and the other with 8 and 18 MV x-ray beams. First, t...

2015
Charbel Merheb Clément Chevillard Wassim Ksouri Maher Fawzi Marc Bollet Alain Toledano

Several algorithms exist to perform quality assurance for volumetric-modulated arc therapy (VMAT) treatments based on electronic portal imaging devices (EPID). These algorithms are used to compare doses (convert into water, GLAaS) and fluences (in amorphous silicon (aSi), Varian portal dosimetry). The aim of this study is to compare the two methods using clinical data. In this study, Varian por...

2017
Stefano Peca Derek Wilson Brown Wendy Lani Smith

PURPOSE To improve patient safety and treatment quality, verification of dose delivery in radiotherapy is desirable. We present a simple, easy-to-implement, open-source method for in vivo planar dosimetry of conformal radiotherapy by electronic portal imaging device (EPID). METHODS Correlation ratios, which relate dose in the mid-depth of slab phantoms to transit EPID signal, were determined ...

E. Bezak, M. Mohammadi,

ABSTRACT Background: for treatment verification in radiation therapy. Several physical characteristics of ScanningLiquid filled Ionization Chamber EPID (SLIC-EPID) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.Electronic Portal Imaging Devices (EPIDs) have found an outstanding positionMaterials and Methods: equilibrium, 1-30 mm white water mat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید