نتایج جستجو برای: head scatter factor sc medical accelerator mini phantom

تعداد نتایج: 1631298  

2012
ANNA TURCO

The work here presented analyzes the performances (in terms of scatter fraction, spatial resolution, sensitivity, image quality) obtained from a 10detectors small-animal PET, simulated via Geant4 Application for Emission Tomography (GATE), in comparison with other designs studied in previous works. Particular attention is given to the comparison with the 12-detectors miniPET II, already built a...

2000
J. C. Huang L. E. Reinstein

A new cubic phantom was designed to improve the efficiency on the QA measurement of accelerator. It has a variety of applications, such as dose constancy check, depth dose verifications, and symmetry and flatness evaluations. In particular, this new design makes it much easier to perform the check on output constancy vs. gantry angles as a cylindrical ion chamber positioned at the center of the...

Journal: :Medical physics 1997
W R Geiser W Huda N A Gkanatsios

An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating the patient (i.e., with-scatter geometry). Patient doses were expressed in terms...

Journal: :Medical physics 2016
D Branco P Taylor S Frank H Li X Zhang H Mehrens M Guindani D Followill

PURPOSE To design a Head and Neck (H&N) anthropomorphic QA phantom that the Imaging and Radiation Oncology Core Houston (IROC-H) can use to verify the quality of intensity modulated proton therapy (IMPT) H&N treatments for institutions participating in NCI clinical trials. METHODS The phantom was created to serve as a remote auditing tool for IROC-H to evaluate an institution's IMPT planning ...

Journal: :British Journal of Psychiatry 1984

Journal: :Kaku igaku. The Japanese journal of nuclear medicine 2007
Akihiro Takaki Satomi Teraoka Tsutomu Soma Tomonori Murakami Akihiro Kojima Masanori Matsumoto Kenya Murase

In order to perform experimental measurements for evaluation of imaging device's performance, data acquisition technique, and clinical images on scintigraphic imaging, many kinds of phantoms are employed. However, since these materials are acrylic and plastic, the thickness and quality of those materials cause attenuation and scatter in itself. We developed a paper sheet phantom sealed with a p...

Journal: :Medical physics 2000
M R Arnfield J V Siebers J O Kim Q Wu P J Keall R Mohan

The main purpose of this work is to demonstrate a practical means of determining the leaf transmission and scatter characteristics of a multileaf collimator (MLC) pertinent to the commissioning of dynamic intensity modulated radiotherapy, especially for the sweeping window technique. The data are necessary for the conversion of intensity distributions produced by intensity-modulated radiotherap...

Journal: :Advances in Science, Technology and Engineering Systems Journal 2020

Journal: :Physics in medicine and biology 2009
Stephen F Kry Rebecca M Howell Jerimy Polf Radhe Mohan Oleg N Vassiliev

The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target...

2013
Hsin-Hui Lee Jyh-Cheng Chen

The quantitative accuracy of SPECT is limited by photon attenuation and scatter effect when photons interact with atoms. In this study, we developed a new attenuation correction (AC) method, CT-based mean attenuation correction (CTMAC) method, and compared it with various methods that were often used currently to assess the AC phenomenon by using the small-animal SPECT/CT data that were acquire...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید