نتایج جستجو برای: hemoglobin oxygen saturation

تعداد نتایج: 295909  

Journal: :Technology in cancer research & treatment 2011
Nrusingh C Biswal Yan Xu Quing Zhu

We present an ultrasound (US)-guided diffuse optical tomography for mapping tumor deoxyhemoglobin (deoxyHb) and oxyhemoglobin (oxyHb) concentrations in blood phantoms and in in-vivo patients. Because oxyHb and deoxyHb respond differently at different wavelengths, four laser diodes of wavelengths 740 nm, 780 nm, 808 nm and 830 nm were used in the study. Tumor model experiments were performed usi...

2013
Richard J. Sove Nour Ghonaim Daniel Goldman Christopher Gerald Ellis

Erythrocytes are proposed to be involved in blood flow regulation through both shear- and oxygen-dependent mechanisms for the release of adenosine triphosphate (ATP), a potent vasodilator. In a recent study, the dynamics of shear-dependent ATP release from erythrocytes was measured using a microfluidic device with a constriction in the channel to increase shear stress. The brief period of incre...

Journal: :The American journal of physiology 1994
W Hasibeder R Germann H Sparr M Haisjackl B Friesenecker G Luz H Pernthaler K Pfaller H Maurer O Ennemoser

The mucosa of the small intestine has some unique microcirculatory features that may result in significant tissue oxygenation changes even under physiological conditions. To prove this hypothesis we investigated mucosal and serosal oxygenation in an autoperfused, innervated jejunal segment in pigs. Eight animals (30-40 kg) were anesthetized, paralyzed, and normoventilated. A small segment of th...

Journal: :Acta anaesthesiologica Scandinavica. Supplementum 1995
R Nijland H W Jongsma J G Nijhuis B Oeseburg W G Zijlstra

Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influences of dyshaemoglobins and fetal haemoglobin on the accuracy of pulse oximetry are discussed. As ...

Journal: :Lasers in surgery and medicine 2012
Amaan Mazhar Seyed A Sharif J David Cuccia J Stuart Nelson Kristen M Kelly Anthony J Durkin

BACKGROUND AND OBJECTIVE Objective methods to assess port wine stain (PWS) response to laser treatment have been the subject of various research efforts for several years. Herein, we present a pilot study using a newly developed, light emitting diode (LED) based spatial frequency domain imaging (SFDI) device to record quantitatively biochemical compositional changes in PWS after laser therapy. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید