In vivo measurement of actinides activity in human skull is a valuable technique of internal dosimetry. Many articles were published on calibrations and some new facts were found. The most important finding was that the relation of measured head size and size of a calibration phantom has notable effect on measured activity; however real impact depends on the detectors geometry. Still opened and...
This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property that the maximum dose occurs very close to the surface and thus, they are predominantly used in the treatment of skin cancers but also have applications for the treatment of other cancers. In addition, kilovoltage...
Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...
PURPOSE A real-time in vivo dosimetric verification method using metal-oxide-semiconductor field effect transistor (MOSFET) dosimeters has been developed for patient dosimetry in high-dose rate (HDR) intracavitary brachytherapy of nasopharyngeal carcinoma (NPC). METHODS The necessary calibration and correction factors for MOSFET measurements in (192)Iridium source were determined in a water p...
Patient-specific image-based dosimetry is considered to be a useful tool to limit toxicity associated with peptide receptor radionuclide therapy (PRRT). To facilitate the establishment and reliability of absorbed-dose response relationships, it is essential to assess the accuracy of dosimetry in clinically realistic scenarios. To this end, we developed pharmacokinetic digital phantoms correspon...
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
An anthropomorphic head phantom, constructed from a water-equivalent plastic shell with only a spherical target, was modified to include a nonspherical target (pituitary) and an adjacent organ at risk (OAR) (optic chiasm), within 2 mm, simulating the anatomy encountered when treating acromegaly. The target and OAR spatial proximity provided a more realistic treatment planning and dose delivery ...
Purpose: To develop and validate a pre-treatment EPI dosimetry method on Varian TrueBeam linacs using continuous imaging, with reconstruction in a 3D cylindrical phantom geometry. Methods: Delivery of VMAT plans with continuous imaging is currently possible only in Research Mode on TrueBeam linacs, with images acquired in a proprietary format. An earlier technique was adapted to take advantage ...
Dose distribution inside the human body due to external photon exposure was measured. Radiation detectors were imaging plate (IP) sheets and thermoluminescent dosimeters (TLD). Each IP sheet was installed between horizontally sliced pieces of a rando-phantom. TLDs were also installed inside/around the position of a target organ of the phantom. The rando-phantom was exposed to a photon beam of C...