نتایج جستجو برای: mini implant

تعداد نتایج: 77423  

Journal: :Journal of clinical and diagnostic research : JCDR 2015
Biswas Palukunnu Padmaprabha Shaji Aboobacker Ponnambathayil Hariprasad Aynipully Midhun Vinod Deepak Parambath Reghunathan

A commonly encountered problem in prosthetic dentistry is the supra eruption of teeth due to absence of opposing teeth. Consequently, replacement of the missing teeth with prosthesis becomes difficult due to lack of vertical dimension of the edentulous area. This article describes the space regaining procedure in a 14-year-old female patient who wanted a fixed prosthesis for her missing maxilla...

2014
Matheus Miotello Valieri Karina Maria Salvatore de Freitas Fabricio Pinelli Valarelli Rodrigo Hermont Cançado

OBJECTIVE To compare the acceptability and effectiveness of topical and infiltration anesthesia for placement of mini-implants used as temporary anchorage devices. METHODS The sample comprised 40 patients, 17 males and 23 females, whose mean age was of 26 years and who were all undergoing orthodontic treatment and in need for anchorage reinforcement. Mini-implants were bilaterally placed in t...

Journal: :European journal of orthodontics 2014
MoonHee Kim Kyung-sim Seol Yoonjung Lee Jiman Park Minji Kim Youn-Sic Chun

OBJECTIVES The aim of this study was to investigate the effects of retraction force and anchorage reinforcement with orthodontic mini implants on occlusal force. MATERIALS AND METHODS A strain gauge was attached to the palatal surface of the maxillary right first molar on an en masse retraction model. RESULTS Occlusal forces were measured from this model, according to different retraction f...

2012
Soon-Yong Kwon Sung-Seo Mo

A1. The temporary skeletal anchorage device used in this study, C-implant, requires higher removal torque compared to other orthodontic mini-implants because of its greater osseointegration potential. It also means that the C-implant allows application of multi-directional force system such as retraction combined with intrusion by concurrent use of intraand intermaxillary elastics. In such case...

Journal: :Journal of oral science 2012
Ken-ichiro Ejima Saori Omasa Mitsuru Motoyoshi Yoshinori Arai Yukiko Kai Toshihiko Amemiya Hisaya Yamada Kazuya Honda Noriyoshi Shimizu

This study aimed to show the effects of metal artifacts on the in vivo micro-CT of mini-implants by measuring bone volume. We drilled a hole in the cortical bone of a rat tibia and embedded a titanium orthodontic mini-implant (diameter, 1.5 mm) in the hole. Twelve individually weighed hydroxyapatite grains (HA grains) were placed around the implant either by one dentist (method 1) or separately...

Journal: :American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics 2006
Tae-Woo Kim Hyewon Kim Shin-Jae Lee

A boy, aged 10.5 years, with a Class II molar relationship and a very deep overbite, complaining of a gummy smile and anterior crowding, was treated nonextraction with a mini-implant and Twin-block and edgewise fixed appliances. Severely extruded and retroclined maxillary incisors were intruded and proclined with a nickel-titanium closed-coil spring anchored to a mini-implant and segmented wire...

2017
Monica Namburi Sleevaraju Nagothu Chetan S. Kumar N. Chakrapani C. H. Hanumantharao Supradeep K. Kumar

BACKGROUND Extraction of premolars and retracting the anterior teeth using mini-implants and anterior retraction hooks became advent now a day. In such treatments, consolidation of arches is not done in regular practice. So, the present study is concentrated on effects of consolidation in two implant and three implant combinations of retraction and intrusion. METHODS A three-dimensional FEM m...

Journal: :The Journal of Indian Orthodontic Society 2022

Introduction: The study was conducted to assess the stress and displacement effects of a mini-implant supported k-loop on maxillary dentition for distalization with 3-dimensional (3D) finite element analysis. Materials Methods: A 3D model maxilla all teeth, periodontal ligament, bone, mini-implants, brackets, archwire used in this study. analytic like wire, K-loop, mini-implants developed using...

Journal: :The International journal of oral & maxillofacial implants 2012
Ali Tahmaseb Renaat De Clerck Irene Aartman Daniel Wismeijer

PURPOSE To evaluate the performance of a computer-aided three-dimensional planning protocol in combination with previously inserted reference mini-implants and CAD/CAM technology to restore completely edentulous patients. The study evaluated implant and superstructure survival in a prospective clinical trial. MATERIALS AND METHODS The plan protocol called for treatment of 35 patients who were...

2017
Ji Hui Choi Ha-Yeon Kim Sung Soo Lee SiHyun Cho

A single-rod subdermal contraceptive implant is usually located around the insertion site, has been usually known to migrate within less than 2 cm of the insertion site and the true migration over 2 cm has been rarely reported. We report a case of migrated radiopaque subdermal contraceptive implant into lung in a 37-year-old woman. On conducted chest computed tomography, subdermal contraceptive...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید