نتایج جستجو برای: mixing index
تعداد نتایج: 458779 فیلتر نتایج به سال:
Gas mixing in a T-shape micro mixer has been simulated using the Direct Simulation Monte Carlo (DSMC) method. It is considered that the adequate mixing occurs when the mass composition of the species, CO or N2, deviates below 1 % from their equilibrium composition. The mixing coefficient is defined as the ratio of the mixing length to the main channel’s height. As the inlet Kn increases, while ...
This research aimed to develop and optimize a nanoemulsion-based formulation containing ceramide IIIB using phase-inversion composition for transdermal delivery. The effects of ethanol, propylene glycol (PG), and glycerol in octyldodecanol and Tween 80 systems on the size of the nanoemulsion region in the phase diagrams were investigated using water titration. Subsequently, ceramide IIIB loadin...
In this study, the mixing phenomena and fluid dynamics in a copper converter have been experimentally investigated using a physical model. The physical model is a 1:5 horizontal tank made of Plexiglas. The mixing phenomena have been characterized by experimentally measuring the mixing time using a tracer dispersion technique. Moreover, the effects of the air flow rate and lance submergence on t...
A numerical study of 3D electrokinetic flows through micromixers was performed. The micromixers considered here consisted of heterogeneous rectangular microchannels with prescribed patterns of zeta-potential at their walls. Numerical simulation of electroosmotic flows within heterogeneous channels requires solution of the Navier-Stokes, Ernest-Plank and species concentration equations. It is kn...
a numerical study of 3d electrokinetic flows through micromixers was performed. the micromixers considered here consisted of heterogeneous rectangular microchannels with prescribed patterns of zeta-potential at their walls. numerical simulation of electroosmotic flows within heterogeneous channels requires solution of the navier-stokes, ernest-plank and species concentration equations. it is kn...
PURPOSE To present and validate a new method for 4D flow quantification of vortex-ring mixing during early, rapid filling of the left ventricle (LV) as a potential index of diastolic dysfunction and heart failure. MATERIALS AND METHODS 4D flow mixing measurements were validated using planar laser-induced fluorescence (PLIF) in a phantom setup. Controls (n = 23) and heart failure patients (n =...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید