نتایج جستجو برای: plate fixation

تعداد نتایج: 121886  

2016
Seong-Sik Kim Kyoung-Ho Kwak Ching-Chang Ko Soo-Byung Park Woo-Sung Son Yong-Il Kim

OBJECTIVE The purpose of the present study was to evaluate the postoperative three-dimensional (3D) changes in the proximal segments after mandibular setback sagittal split ramus osteotomy and to compare the changes between the conventional mini-plate fixation and semi-rigid sliding plate fixation. METHODS Cone-beam computed tomography (CBCT) images were used to evaluate the postoperative 3D ...

2012
Kyoung In Yun Young-Gyu Cho Jong-Min Lee Yoon-Hee Park Myung-Kyun Park Je Uk Park

J Korean Assoc Oral Maxillofac Surg 2012;38:271-5) Objectives: This study evaluated a range of fixation methods to determine which is best for the postoperative stabilization of a mandibular osteotomy using three-dimensional finite element analysis of the stress distribution on the plate, screw and surrounding bone and displacement of the lower incisors. Materials and Methods: The model was gen...

2018
Adeel Anwar Zhen Zhang Decheng Lv Gang Lv Zhi Zhao Yanfeng Wang Yue Cai Wasim Qasim Muhammad Umar Nazir Ming Lu

BACKGROUND Clinically there are different fixation methods used for fixation of the posterior malleolar fractures (PMF), but the best treatment modality is still not clear. Few studies have concentrated on this issue, least of all using a biomechanical comparison. The purpose of this study was to carry out a computational comparative biomechanics of three different commonly used fixation constr...

Journal: :Canadian journal of surgery. Journal canadien de chirurgie 2005
Mark M Harrison James P Waddell

PURPOSE To compare 2 methods of fixation for maintenance of alignment during healing of valgus tibial osteotomies. METHODS We performed a retrospective chart and radiographic review of valgus tibial osteotomy cases of staple fixation supplemented by a postoperative cast and of blade plate fixation for maintenance of femoral-tibial alignment during healing of the osteotomy. RESULTS Both grou...

2012
Yukio Abe Yasuhiro Tominaga

Distal radius fracture (DRF) is one of the most common traumatic events for the hand surgeon to treat. Numerous surgical procedures have been described for this fracture (Ruch et al., 2004); however, the ideal method of surgical management is still controversial. The latest development of a volar locking plate fixation markedly changed the treatment of DRF (Chen & Jupiter, 2007; Chung et al., 2...

Journal: :The Journal of hand surgery, European volume 2011
J Kraisarin D G Dennison L J Berglund K N An A Y Shin

Clinical results following four-corner arthrodesis vary and suggest that nonunion may be related to certain fixation techniques. The purpose of our study was to examine the displacement between the lunate and capitate following a simulated four-corner arthrodesis with the hypothesis that three types of fixation (Kirschner wires, dorsal circular plate, and a locked dorsal circular plate) would a...

Journal: :surgery and trauma 0
reza rbdi assistant professor, department of pediatric orthopedics, faculty of medicine, birjand university of medical sciences, birjand, iran moein aboobakri emam reza hospital, birjand, iran

introduction: intramedullary nailing (imn) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. however, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated imn fixation of proximal high tibia fracture. the purpose of this study is to determine the effectiveness of using 3.5-mm locking c...

2016
Yan Gao Wei Chen Yue-Jv Liu Xu Li Hai-Li Wang Zhao-yu Chen Li Zuo

Background. Plate fixation and intramedullary fixation are the most commonly used surgical treatment options for mid-shaft clavicle fractures; the latter method has demonstrated better performance in some studies. Objectives. Our aim was to critically review and summarize the literature comparing the outcomes of mid-shaft clavicle fracture treatment with plate fixation or intramedullary fixatio...

2014
Stefanie Doht Rainer H Meffert Michael J Raschke Torsten Blunk Sabine Ochman

PURPOSE To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. METHODS Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduction and stabilization with a nonlocking and a comparable locking plate in mono- or bicortical sc...

Journal: Surgery and Trauma 2016

Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید