نتایج جستجو برای: power system harmonics

تعداد نتایج: 2587527  

2014
Sanjeev Kumar Ojha Madhur Chauhan

The non-linear loads include rectifiers, blenders, electric drills, UPS, computer, printer, TV’s, variable speed drivers, arc furnaces and high power electronic equipment comprising high power semiconductors i.e thyristorised Converters, Inverters etc. It is well known that any deviation from a perfect sin-wave is an indication of the presence of harmonics in the power system. Hence, a pure alt...

Journal: :The Transactions of The Korean Institute of Electrical Engineers 2014

2016
Vikas Kumar Chandra Mahendra Kumar Pradhan

Ac to DC converter is used for operating DC electrical machine and also supplies DC power to battery which is used for many purposes. The main purpose of this project is to compensate the harmonics by using harmonic current compensation and reactive power control. If reactive power is compensate prior to system then non linearity or harmonics present in the system does not much affect the exist...

A. Ghassemi E. zarezadeh S. Saeed Fazel

AC railway traction loads are usually huge single phase loads. As a result, a significant amount of Negative Sequence Current (NSC) is injected into utility grid. Moreover, harmonics and consumption ofreactive power are further power quality problems that the supply network is encountering. In this paper, acompensation strategy with the aid of Railway Power Conditioner (RPC) is proposed to over...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تبریز 1388

چکیده ندارد.

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

2007
MANUELA PANOIU CAIUS PANOIU MIHAELA OSACI IONEL MUSCALAGIU

This paper present the results obtained by simulation for the functioning regime improvement of an UHP Electric Arc Furnace. Because the nonlinearity of the electric arc the EAF functioning regime are perturbed from three causes: the current harmonics, the reactive power and the unbalanced load. In this paper there are study the possibilities of harmonics filtering and compensate the reactive p...

G. Ardeshir M. Niaboli Guilani

An effective technique for mixer LO harmonic rejection in a SAW-less wideband receiver front-end is proposed. The proposed technique provides a tunable notch that can be placed at any frequency like mixer LO harmonics, to avoid the aliasing in baseband after mixing. An analog LC notch is used in a cascode transconductor, and it can reject one of the 3rd or 5th harmonics. T...

2013
Mini K. Namboothiripad

Reactive power compensation in a power distribution network plays a vital role in improving voltage and power system stability. Flexible AC transmission system (FACTS) devices like Static Var Compensators (SVCs) are used to control reactive power generation or absorption in long transmission line. However, these SVCs will introduce harmonic current in to the system due to the operation of thyri...

2013
Mridula sharma

with increase in traffic and speed railway became one of the major load on supply grid .AC-DC convertor used in locomotive of traction system draws rich harmonics content current results in poor power quality and failure or missed operation of utility causing derating of grid and affect the reliability. This paper provide framework for issue like harmonics, voltage sage ,voltage unbalance, poor...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید