نتایج جستجو برای: proximal humeral fracture
تعداد نتایج: 161555 فیلتر نتایج به سال:
OBJECTIVES The PROximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial has recently demonstrated that surgery is non-superior to non-operative treatment in the management of displaced proximal humeral fractures. The objective of this study was to assess current surgical practice in the context of the PROFHER trial in terms of patient demographics, injury characteristics an...
BACKGROUND Fractures of the proximal humerus are associated with a profound temporary and sometimes permanent, impairment of function and quality of life. The treatment of comminuted fractures of the proximal humerus like selected three-or four-part fractures and split fractures of the humeral head is a demanding and unresolved problem, especially in the elderly. Locking plates appear to offer ...
BACKGROUND With new minimally-invasive approaches for angular stable plate fixation of proximal humeral fractures, the need for the placement of oblique inferomedial screws ('calcar screw') has increasingly been discussed. The purpose of this study was to investigate the influence of calcar screws on secondary loss of reduction and on the occurrence of complications. METHODS Patients with a p...
BACKGROUND The optimal treatment for proximal humeral fractures remains under debate. In this article, we report the mid-term results of patients who underwent the less-invasive implantation of a polyaxial locking plate for displaced proximal humeral fractures. METHODS This study included patients who were treated with a polyaxial locking plate via an anterolateral deltoid split approach from...
PURPOSE To report the outcome after minimally invasive plate osteosynthesis (MIPO) through the deltoid-splitting approach for proximal humeral fractures. METHODS 10 men and 30 women aged 37 to 88 years underwent MIPO through the deltoid-splitting approach using the Proximal Humerus Internal Locking System or the Locking Proximal Humerus Plate for 2-part (n=18), 3-part (n=20), and 4-part (n=2)...
OBJECTIVES The use of locked plates in repairing osteopenic 3- and 4-part proximal humerus fractures remains controversial. The purpose of this article was to report the outcomes of open reduction and internal fixation in low-energy proximal humerus fractures treated with locked plating in patients older than 55 years and stratify risk of failure or complication based on initial radiographic fe...
BACKGROUND Open reduction and internal fixation (ORIF) of complex fractures of the proximal humerus may yield unsatisfactory results. This study analyzed the results obtained after revision of failed ORIF of proximal humeral fractures using reverse total shoulder arthroplasty (RTSA). METHODS Fifty-four shoulders of 53 patients with a subjectively unacceptable outcome after ORIF of a complex f...
OBJECTIVES This investigation sought to advance the work published in our prior biomechanical study (Journal of Orthopaedic Research, 2016). We specifically sought to determine whether there are additional easy-to-measure parameters on plain radiographs of the proximal humerus that correlate more strongly with ultimate fracture load, and whether a parameter resembling the Dorr strength/quality ...
Alterations have been made over the years to the standard reverse total shoulder arthroplasty (RTSA) prosthetic components in an effort to decrease adverse events; this has led to the advent of a short humeral stem prosthesis. To the authors' knowledge, there are no reports describing the complication of a traumatic periprosthetic Wright and Cofield classification type A fracture with use of a ...
Minimally invasive plate osteosynthesis (MIPO) has been used for humeral shaft fractures, but concerns exist about soft tissue injuries. The purpose of this study was to report the surgical technique and clinical outcomes of MIPO using a helical plate for metadiaphyseal complex humeral shaft fractures. Twelve patients with acute displacement involving proximal and middle third humeral shaft fra...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید