نتایج جستجو برای: rectal retractor prostate cancer radiotherapy rectum

تعداد نتایج: 988414  

2007
Mohamed Metwaly Awaad Mousa Awaad El‐Sayed Mahmoud El‐Sayed Abdel Sattar Mohamed Sallam

In this study, we present an intensity-modulated radiotherapy technique based on forward planning dose calculations to provide a concave dose distribution to the prostate and seminal vesicles by means of modified dynamic arc therapy (M-DAT). Dynamic arcs (350 degrees) conforming to the beam's eye view of the prostate and seminal vesicles while shielding the rectum, combined with two lateral obl...

2013
Shiv P. Srivastava Indra J. Das Arvind Kumar Peter A. S. Johnstone Chee‐Wai Cheng

The use of rectal balloon in radiotherapy of prostate cancer is shown to be effective in reducing prostate motion and minimizing rectal volume, thus reducing rectal toxicity. Air-filled rectal balloon has been used most commonly, but creates dose perturbation at the air-tissue interface. In this study, we evaluate the effects of rectal balloon-filling materials on the dose distribution to the t...

Journal: :The Journal of urology 2004
Peter Wust Daniel Wischka von Borczyskowski Thomas Henkel Christian Rosner Reinhold Graf Wolfgang Tilly Volker Budach Roland Felix Frank Kahmann

BACKGROUND AND PURPOSE To assess acute as well as long-term toxicity after permanent prostate seed implantation. To find predictive clinical or dosimetric factors for side effects in order to work out strategies for improvement. PATIENTS AND METHODS A group of 174 patients with localised prostate cancer was treated with permanent seed implantation between 1999 and 2001, either alone (140 pati...

Journal: :iranian journal of medical physics 0
hassan ali nedaie radiotherapy oncology department, cancer research center, cancer institute, tehran university of medical sciences, tehran, iran. nooshin banaee young researchers and elites club, science and research branch, islamic azad university, tehran, iran.

introduction intensity-modulated radiotherapy (imrt) is becoming an increasingly routine treatment method. imrt can be delivered by use of conventional multileaf collimators (mlcs) and/or physical compensators. one of the most important factors in selecting an appropriate imrt technique is integral dose. integral dose is equal to the mean energy deposited in the total irradiated volume of the p...

2014
Nadine Beydoun Joseph Bucci David Malouf

PURPOSE Prostate cancer is among the most common non-cutaneous neoplasms affecting renal transplant recipients (RTRs). Available treatments including radical prostatectomy and external beam radiotherapy carry a risk of damage to the transplanted kidney, ureters, or bladder. We assessed the safety and efficacy of Iodine-125 ((125)I) prostate seed brachytherapy as an alternative to surgery and ra...

Journal: :Palliative Medicine in Practice 2022

Background: Rectal cancer patients require a multidisciplinary approach. In the case of locally advancedrectal standard treatment includes neoadjuvant radiotherapy or chemoradiotherapy. Neoadjuvanttreatment could cause postoperative complications, but there is no clear evidence an associationbetween anastomotic leakage and preoperative rectal cancer. This study aimed toinvestigate frequency fol...

2014
Hideya Yamazaki Satoaki Nakamura Takuya Nishimura Ken Yoshida Yasuo Yoshioka Masahiko Koizumi Kazuhiko Ogawa

With the advent of modern radiation techniques, we have been able to deliver a higher prescribed radiotherapy dose for localized prostate cancer without severe adverse reactions. We reviewed and analyzed the change of toxicity profiles of external beam radiation therapy (EBRT) from the literature. Late rectal bleeding is the main adverse effect, and an incidence of >20% of Grade ≥2 adverse even...

Journal: :International journal of radiation oncology, biology, physics 2007
Carlos Vargas Chaitali Mahajan Amber Fryer Daniel Indelicato Randal H Henderson Craig McKenzie David Horne Angela Chellini Paula Lawlor Zuofeng Li Kenneth Oliver Sameer Keole

PURPOSE To describe dose-volume values with the use of water alone vs. a rectal balloon (RB) for the treatment of prostate cancer with proton therapy. MATERIALS AND METHODS We analyzed 30 proton plans for 15 patients who underwent CT and MRI scans with an RB or water alone. Simulation was performed with a modified MRI endorectal coil and an RB with 100 mL of water or water alone. Doses of 78-...

Journal: :Practical radiation oncology 2017
Benjamin W Fischer-Valuck Anupama Chundury Hiram Gay Walter Bosch Jeff Michalski

PURPOSE Hydrogel prostate-rectum spacers, biomaterials placed between the prostate and rectum, continue to gain interest as a method to reduce or limit rectal dose during dose escalated prostate cancer radiation therapy. Because the spacer is initially injected into the perirectal space as a liquid, the final distribution can vary. The purpose of this study was to evaluate hydrogel spacer (Spac...

Journal: :iranian journal of medical physics 0
seyed mostafa ghavami department of radiology, paramedical school, tabriz university of medical sciences, tabriz, iran hosein ghiasi medical radiation sciences research team, tabriz university of medical sciences tabriz, iran

introduction accurate estimation of the skin-absorbed dose in external radiation therapy is essential to estimating the probability of secondary carcinogenesis induction materials and methods electron contamination in prostate radiotherapy was investigated using the monte carlo (mc) code calculation. in addition, field size dependence of the skin dose was assessed. excess cancer risk induced by...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید