نتایج جستجو برای: reheater tubes

تعداد نتایج: 27300  

2010
Elpis Giantsou Kevin J. Gunning John V. Farman

Purpose of review: This article reviews the thoracic complications from malpositioned blindly inserted nasogastric feeding tubes in mechanically ventilated patients in intensive care and the methods to check the position and promote safe placement of the feeding tubes. Recent findings: Malpositioned feeding tubes are not included in risk management databases. The reported incidence is 1-3% and ...

Journal: :Journal of clinical pathology 1981
A D Heyns D J van den Berg P H Kleynhans P W du Toit

Activated partial thromboplastin times (APTT) for monitoring heparin therapy for venous thromboembolism tended to be inappropriately short if blood was collected in commercially available evacuated glass tubes. Five types of evacuated tubes marketed under the trade names Vacutainer and Venoject were examined. The APTT of heparinized blood collected in these tubes correlated poorly (r = 0.04 to ...

Journal: :Pacific Symposium on Biocomputing. Pacific Symposium on Biocomputing 1998
L Priese Y Rogojine M Margenstern

Finite H-systems with n test tubes are splicing systems of n test tubes over a common molecular alphabet, sigma, with a filter Fi [symbol: see text] sigma for each test tube. Initially, arbitrary many copies of molecules and enzymes (splicing rules) from a finite set of molecules and enzymes are given to the test tubes that produce new molecules by splicing and filtering. It is known that any f...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2015
komeil mohebbi rohollah rafee farhad talebi

in this paper, convection heat transfer of al2o3-water nanofluid turbulent flow through internally ribbed tubes with different rib shapes (rectangular, trapezoidal and semi-circular) is numerically investigated. for each rib shape, the optimum geometric ratio and volume fraction were calculated using entropy generation minimization technique. the governing equations in steady state and axisymme...

Journal: :Clinical chemistry 1984
Y Bergqvist S Eckerbom L Funding

We evaluated the effect on drug concentration of the duration of sample storage in three different tubes for blood collection: SST (Becton Dickinson), AutoSep (Terumo), and Microvette (Sarstedt), all of which contain an inert barrier (e.g., gel) for cleaner separation of serum from coagulum during centrifugation. With two of the tubes (SST and AutoSep) we examined samples taken from patients un...

2016
Songlin Yu Weiyan Zhou Xinqi Cheng Huiling Fang Ruiping Zhang Qian Cheng Jianhua Han Wei Su Liangyu Xia Ling Qiu

A significant bias was found when using the Siemens ADVIA Centaur XP system for measurement of 25-hydroxyvitamin D (25OHD) with VACUETTE® tubes with Serum Clot Activator and Gel. Here, we examined whether other commonly used tubes or temperatures affected 25OHD results obtained with the Siemens ADVIA Centaur XP system. Serum was collected into five types of vacuum blood collection tubes from th...

Journal: :Annals of clinical and laboratory science 2013
Geling Li Michael Cabanero Zhenglong Wang Huiying Wang Tao Huang Herol Alexis Ikram Eid Gilad Muth Matthew R Pincus

Because of the metabolism of serum glucose in collection tubes containing blood samples, serum glucose levels may be found to decrease over time. Several types of collection tubes have been designed to, at least partially, block glucose metabolism by red blood cells in blood collection tubes that may not be analyzed immediately after blood collection. These include red-top collection tubes with...

2005
DJ VAN DEN BERG PHT KLEYNHANS

Activated partial thromboplastin times (APTT) for monitoring heparin therapy for venous thromboembolism tended to be inappropriately short if blood was collected in commercially available evacuated glass tubes. Five types of evacuated tubes marketed under the trade names Vacutainer and Venoject were examined. The APTT of heparinised blood collected in these tubes correlated poorly (r = 004 to r...

Journal: :SIAM J. Control and Optimization 2006
Alexander B. Kurzhanski Pravin Varaiya

The paper presents a scheme to calculate approximations of reach sets and tubes for linear control systems with time-varying coefficients, bounds on the controls, and constraints on the state. The scheme provides tight external approximations by ellipsoidal-valued tubes. These tubes touch the reach tubes from the outside at each point of their boundary so that the surface of the reach tube is t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید