نتایج جستجو برای: rise buildings

تعداد نتایج: 174490  

2013
Se Woon Choi Yousok Kim Jong Moon Kim Hyo Seon Park

The automatic monitoring of shortenings of vertical members in high-rise buildings under construction is a challenging issue in the high-rise building construction field. In this study, a practical system for monitoring column shortening in a high-rise building under construction is presented. The proposed monitoring system comprises the following components: (1) a wireless sensing system and (...

In this study, the seismic inter-story drift of structures is estimated by a combination of mode-acceleration equations with the modelling of high-rise buildings with flexural and shear cantilever beams. In the equation presented for calculating the inter-story drift, having less knowledge of the building is adequate and this issue is of significance in estimating the nonstructural component fo...

Mashhad city is located on alluvial deposits where the expanded area of this city, especially the central and eastern areas surrounding Imam Reza holy shrine, are built on weak and fine-grained deposits. Therefore, the soil improvement would be inevitable due to construction of high-rise buildings such as hotels and commercial complexes in these areas, as well as restructuring old buildin...

2015
Jelena Pejović Srđan Janković

The relationship between the ground motion intensity measure (IM) and the engineering demand parameter (EDP) is analysed in the paper so as to identify and define the most efficient EDP-IM relationships for RC high-rise buildings. A 30-story RC high-rise building with the core wall structural system was selected as the reference building. 240 nonlinear time-history analyses were conducted for 6...

2002
D. E. Grierson

The paper presents a computer-based method for the multicriteria conceptual design of engineered artifacts. The proposed method involves genetic-based stochastic search, Pareto optimization, and color-filtered graphics. A multicriteria genetic algorithm broadly searches the governing body of design knowledge and identifies Pareto designs that are equal-rank optimal in the sense that each is not...

2006
B. B. BLEVINS

As part of the adoption of the 2005 Building Energy Efficiency Standards, the California Energy Commission adopted Joint Appendix IV, which contains standard U-factor, C-factor and Thermal Mass data for roof, wall and floor construction assemblies (see page IV-1 of the Joint Appendices at: http://www.energy.ca.aov/title24/2005standards/2004-10-06 400-03-001JAF.PDF). The data in Joint Appendix I...

F. Nateghi-A and N.A. Hosseinzadeh,

This paper presents a methodology for the assessment of ductility and strength capacities in low-rise buildings. This method utilizes the characteristics of force-displacement for the lowest story level or considers the weakest story in any given low-rise building for its primary analysis. Calculations are based on two levels of earthquake motions, namely strong earthquakes (PGA=0.3 g), and ver...

2016
Guiyun Yan Fuquan Chen Yingxiong Wu

Different from previous researches which mostly focused on linear response control of seismically excited high-rise buildings, this study aims to control nonlinear seismic response of high-rise buildings. To this end, a semi-active control strategy, in which H∞ control algorithm is used and magneto-rheological dampers are employed for an actuator, is presented to suppress the nonlinear vibratio...

2007
M. Ofelia Moroni

Buildings with cast-in-situ reinforced concrete shear walls are widespread in many earthquake-prone countries and regions, such as Canada, Chile, Romania, Turkey, Colombia, the republics of the former Soviet Union, etc. This type of construction has been practiced since the 960s in urban regions for mediumto high-rise buildings (4 to 35 stories high). Shear wall buildings are usually regular in...

F. Nateghi-A and N.A. Hosseinzadeh,

This paper presents a methodology for the assessment of ductility and strength capacities in low-rise buildings. This method utilizes the characteristics of force-displacement for the lowest story level or considers the weakest story in any given low-rise building for its primary analysis. Calculations are based on two levels of earthquake motions, namely strong earthquakes (PGA=0.3 g), and ver...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید