نتایج جستجو برای: shunt active power filter sapf
تعداد نتایج: 1024582 فیلتر نتایج به سال:
Despite its many advantages, the conventional direct power control (DPC) of shunt active power filters (SAPF) poses some problems. This paper investigates the design of a new control technical combining DPC control and passivity theory (PT) to ensure quasi-sinusoidal grid currents, under various conditions of the source voltages. The proposed approach (DPC-PT) appeals to the theory of symmetric...
In this paper control of Goertzel Algorithm based shunt active power filter with sliding mode controller is considered. Shunt active power filter involves harmonics mitigation due to three phase non linear loads under balanced and unbalanced load conditions. The sliding mode controller is used to regulate voltage of the capacitor used in inverter. The sliding mode controller improves the dynami...
Aims: To carried out performance analysis of a shunt active power filter (SAPF) for harmonics mitigation.
 Study Design: Experimental design through simulation studies using P-Q Theory and proportional integral controller.
 Place Duration Study: Department Physics, Nasarawa State University Keffi, main campus, Nigeria, between October 2020 September 2021.
 Methodology: Primary se...
This paper investigates mitigation of current harmonics using different configuration of cascaded multilevel inverter based shunt hybrid active power filter (SHAPF) and to improve power quality of the system. The main objective of this paper is to develop and analyze the compensation characteristics of cascaded multilevel inverter based shunt hybrid active power filter by employing indirect cur...
This research focuses on the analysis and design of robust direct power control (DPC) for a shunt active filter (SAPF). The study proposes novel switching table based an impact inverter vectors derivatives instantaneous reactive powers. goal is to reduce number commutations by eliminating null while maintaining desired DC-bus voltage using PI regulator-based anti windup technique. Additionally,...
Unified power quality conditioner (UPQC) with energy storage is commonly based on conventional capacity configuration strategy angle control. It has problems such as phase jumping before and after compensation. DC-link cannot continuously emit active externally. Therefore, this paper presents the compensation of full load voltage magnitude in UPQC. The topology UPQC integrated a series filter (...
A new control technique known as inverted error deviation (IED) control is incorporated into the main DC-link capacitor voltage regulation algorithm of a three-level neutral-point diode clamped (NPC) inverter-based shunt active power filter (SAPF) to enhance its performance in overall DC-link voltage regulation so as to improve its harmonics mitigation performances. In the SAPF controller, DC-l...
-As the use of power electronic equipment is spreading, the degradation of the power quality in the utility networks is increasing and is becoming a major problem. Limiting the current distortion is therefore a concern for both utilities and consumer. Power converters such as rectifiers, power supplies and at a higher power level, arc furnaces are the sources of harmonics. This harmonics can be...
Chapter 3 presents ANN based adaptive shunt passive filter, whose performance is found to be superior to fixed element shunt passive filter in harmonic and reactive compensation. However, the drawback is that it can provide only partial harmonic and reactive power compensation. Hence, an ANN based digital controller for active filter is developed. It compensates for the major portion of source ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید